| MIL-I-85365(AS)
4.4.1 Sample size Thirty-two igniters shall be subjected to first article inspection.
4.42 inspection routine. The sample shall be subjected to all the inspections and
tests of 4.6 in accordance with the testing schedule of figure 1.
4.4.3 Failure. Failure of any igniter in the sample to meet the above requirements
shall be cause for refusal to grant first article approval.
4.5 Quality conformance inspection. Quality conformance inspection shall consist
of all the examinations and tests as noted in Table II. The minimum production inspection
to be performed shall be in accordance with MIL-STD-105 105 and shall consist of all the
requirements including the classification of defects listed on the applicable drawings.
Acceptance shall be in accordance with 4.8.
TABLE II. Quality conformance inspection
4.5.1 Inspection lot. An inspection lot shall consist of igniters manufactured from
one batch of main charge pellets and one lot of initiators.
4.5.2 Sampling.
4.5.2.1 Circuit resistance sampling All igniters in a lot shall be tested for con-
formance to the circuit resistance requirements (see 3.3).
4.5.2.2 Performance requirements sampling. Sampling of loaded assembly igniters for
conformance to the performance requirements in 3.4 for each temperature shall be in
accordance with MIL-STD-414 14, Table A2, Inspection Level 111. Inspection Level 11 shall
only be used after 3 consecutive accepted lots have been manufactured. If a lot fails,
Level III once again shall be in effect.
46 First article tests,
4.6.1 Visual examination. The igniters shall be examined for conformance to 3.1.