MIL-I-85889(AS)
4.4.1.2 Manufacture of hazard test items. The contractor shall manufacture hazard test items in accordance
with the approved Level 3 drawings.
4.4.1.3 Manufacture of electromagnetic compatibility test item. The contractor shall manufacture an
electromagnetic compatibility test item with inert components. The test unit shall be equipped with 20 spare inert
electrical initiation assemblies.
4.4.1.4 Manufacture of static display model. The contract or shall manufacture a cut-away model of the igniter.
The model shall depict all components in proper relationship to one another. All components shall be inert. The
model shall be equipped with a stand and carrying case.
4.4.1.5 Manufacture of containers. The contractor shall manufacture a sufficient number of containers to perform
Phase Ill test and evaluation of Type II igniters.
4.4.2 Tests.
4.4.2.1 Environments qualification tresting. The contractor (or other activity designated by the contracting
activity see 6.2) shall demonstrate that the igniter design is capable of with standing representative Iii cycle stresses
by subjecting test items to the series of environments specified in table IX or X, as applicable.
4.4.2.2 Hazard assessment tests. The contractor Shall subject the igniter to hazard assessment tests in
accordance with the approved test plan (see 4.3.4.10). Results shall be interpreted in accordance with the definitions
of NAVSEAINST 8010.5 and shall be reported in the Safety Test Report (see 4.4.4.6).
4.4.2.3 Interface demonstration. The contractor shall install a rocket motor with a Type II igniter on the
designated platform(s) to demonstrate physical compatibility. The igniter maybe inert as long as all physical interface
characteristics are maintained Type I and Type II igniters shall be electrically connected to the firing circuit to
demonstrate physical compatibility of connectors. The installed igniter shall be photographed for documentation
purposes. Results of the interface demonstrative shall be documented in the design qualification report (see 4.4.4.5).
TABLE IX. Environmental qualtification test matrix for Type I igniters.
18