Click here to make tpub.com your Home Page

Page Title: Intervalometer environmental tests
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-L-48063A(MI)
4.3.3.6.2 Arm circuit test (see 3.4.4 and 3.4.7). Critical defect -
Intervalometers shall be tested 1 00% for compliance with the requirements.
Any intervalometer failing to comply with the requirements shall be
classified defective and removed from the lot. The test shall be conducted
as specified in 4.4.6.2 using equipment in accordance with 4.3.4.
4.3.3.7 Simulated firing test (see 3.4.3).  Major defect -
Intervalometers shall be selected from each lot as per MIL-STD-105, General
Inspection Level II, and tested for proper timing and output current.
If any intervalometer fails to meet all timing and output current require-
ments for single and ripple modes, the lot shall be rejected. The test
shall be conducted as specified in 4.4.7 using equipment in accordance
with 4.3.4.
4.3.3.8 Intervalometer bypass test (see 3.4.5).  Major defect -
The intervalometers from the simulated firing test shall be tested in
single and ripple modes for compliance with the bypass requirement,  In any
intervalometer fails to meet the requirement, the lot shall be rejected.
The test shall be conducted as specified in 4.4.8 using equipment in
accordance with 4.3.4.
4.3.3.9 Intervalometer environmental tests (see 3.4.11).  Major
defect - When the intervalometer is being procured separately a sample
of intervalometers per MIL-STD-105, General Inspection Level II shall be
selected from each lot and subject to environmental tests as specified
below.  If any intervalometer fails any requirement, the lot is rejected.
a.
Two (2) in accordance with humidity (3.4.11.1).
b. Two (2) in accordance with salt fog (3.4.11.7).
c.
Two (2) in accordance with shock (3.4.11.3).
d. Two (2) in accordance with high temperature (3.4.11.5) and low
temperature (3.4.11.6).
e. Two (2) in accordance with vibration (3.4.11.8) and static firing
(3.4.11.9).
The test shall be conducted as specified in 4.4.9 using equipment in
accordance with 4.3.4.
4.3.3.10 Additional intervalometer environmental tests for first
article (see 3.4.11).
a. Two (2) in accordance with sand and dust (3.4.11.2),
b. Two (2) in accordance with acceleration (3.4.11.4).
Two (2) in accordance with high temperature (3.4.11.5) and low
temperature  (3.4.11.6).
d. Two (2) in accordance with life (3.4.10).
22