| MIL-L-48307B(MIJ)
3.3.4.1.2 Humidity. - Conditions specified in Method 507.1, Procedure II,
MIL-STD-81O, except the number of humidity cycles will be limited to one.
3.3.4.1.3 Altitude. - Conditions specified in Method 500.1, procedure I,
-
M I L - S T D - 8 1 O , exe the chamber pressure will be limited to 10,000
feet.
3.3.4.2 Non-operating conditions. - The laser trainer in the
non-operating, de-energized condition, shall show no evidence of damage
or deterioration and shall meet all requirements of 3.3.5 after the
following environmental exposure.
3.3.4.2.1 Storage temperature. - Thermal stabilization at -65F for
24 hours and +155F for 24 hours.
3.3.4.2.2 Vibration "A". - Conditions specified in Method 514.2, Pro-
cedure VIII, Curve V, Figure 514.2-6, MIL-STD-810 (except that the resonance
dwell time is to be deleted), with the laser trainer mounte horizontallY
in an M73 Machine Gun Mount or equivalent simulation.
3.3.4.2.3 Vibration "B". - Conditions specified in Method 514.2,
Procedure X, Curie AX, Figure 514.2-7, MIL-STD-810, with the laser trainer
properly stored in Case, Drawing No. F11743778.
3.3.4.2.4 Shock. - Conditions specified in Method 516.2, Procedure I,
figure 516.2-1, shock parameters (a) and (c) and Procedure II (limit to 30
inches and V, MIL-STD-810.
3.3.4.2.5 Altitude.- Conditioner specified in Method 500.1, Procedure I,
MIL-STD-81O.
3.3.4.2.6 Sunshine.- Conditions specified in Method 505.1, Procedure I,
MIL-STD-81O.
3.3.4.2.7 Rain.- Conditions specified i nMethod 506.1, Procedure I,
MIL-STD-81O.
3.3.4.2.8 Humidity.- Conditions specified in Method 507.1, Procedure IV,
Figure 507.1-3, MIL-STD-810,
3.3.4.2.9 Salt fog- Conditions specified in Method 509.1, Procedure I,
MIL-STD-81O.
3.3.4.2.10 Dust.- Conditions specified in Method 510.1, Procedure I,
MIL-STD-81O.
3.3.4.2.11 Fungus.- Conditions specified in Method 508.1, Procedure I,
MIL-STD-81O.
4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |