| MIL-L-85347A(AS)
TABLE IV. Classification of defects for visual examination of the life preserver.
(See 4.7.1.1) -Continued
Minor
Critical
211.
12.
Any component, component part
Excessive wrinkling in any
cementing operation. 3/
or required operation omitted;
or any operation improperly
212.
Any inflatable section seam
performed, not herein
classified. 2/
construction which exceeds the
maximum requirements specified.
Any component not as specified
3/
or any defect of a component
213.
or assembly not herein
Cement on the cloth surfaces
classified. 2/
around the patches, attachments,
seams, seam tape not visible or
in excess of requirement. 3/
214.
Any clot or mass of adhesive.
215.
Overlap of seam tape in excess
of requirements.
Any seam tape, patch, or
216.
attachment separating.
-- --.
1/ Any defect shall be classified critical if it appears in MIL-C-19002
fabric.
No more than two or a combination of two contiguous broken or
missing picks, tight ends, knots or burrs, or creases are permitted in a "6
x 3" area of the finished casing of MIL-C-81814 fabric. Baggy, ridgy, wavy
and defects which allow light transmission shall be scored as critical in
the casing fabric (MIL-C-81814).
2/ The defect shall be classified Critical when it seriously affects
serviceability or function; otherwise it is to be classified Minor.
3/ The defect shall be classified as Minor when it does not seriously affect
serviceability or function; otherwise, it is to be classified Critical.
I
4/ The snap fasteners shall be checked for proper function and attachment.
20
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |