| MIL-L-85347A(AS)
TABLE IV.
Classification of defects for visual examination of the life preserver.
(See 4.7.1.1)
Minor
Critical
.
201.
Stitching and sewed seam con-
1.
Any non-specified hole, cut,
patch or burn.
202.
2.
Any fabric damaged, bruised
abraded, containing imperfec-
tions, or is otherwise defec-
203.
tive. 1/
Any stitching in the Inflatable
3.
section of the life preserver.
204.
4.
Any grommet missting, mislocated
or improperly clinched. 2/
205.
5.
Inflation assembly or manifold
stem assembly not in accordance
with requirements, not located
as specified or Inoperable.
Any seam separating in the
206.
6.
inflatable section.
7.
Any inflatable section seam
construction which does not
meet the minimum requirement
207.
specified.
Any seam tape not applied to
8,
seams as specified. 2/
9.
Any channels, or voids in any
208.
seam on the inflatable section.
Inflatable sections and
0.
209.
casing assembly not joined,
as specified.
1.
Oral inflation assembly mis-
located, blend, distorted or
210.
Inoperable.
warning'tag missing, Illegible,
Oral tube clamp
2/
incomplete, Incorrect or
not Installed securely.
improperly located.
19
|