MIL-M-29399(MC)
3.4.3 Capstan/container unloading.  The time required to unload
the equipment of a fully loaded line charge container through the
LVTP7A1 ramp opening shall not exceed 36 seconds when using the
capstan motor.
The time required for the
3.4.4 Launcher raising (powered).
loaded laucher (three rockers  on the rails) to open the unlatched
launcher doors and continue raising until it contacts the launcher
stop at the aft end of the launcher housing shall not exceed 33
seconds, when driven by the motor driven hydraulic pump.
3.4.5 Launcher lowering(powered).  The time required for the load
launcher to lower to its maximum downward position and close the
launcher doors shall not exceed 33 seconds when driven by the motor
driven hydraulic pump.
3.4.6 launcher raising (manual).  Not more than 175 pump strokes
shall be required to raise the loaded launcher to its full up
position when using the emergency hand pump.
3.4.7 Hydraulic motor pump
The hydraulic motor pump shall provide
a flow of 1.8 gallons per minute (gpm) 0.1 gpm at 2000 50 pound-
force per square inch gage (psig) when supplied with a nominal 24
Vdc.
3.4.8 Hydraulic hand pump.  The hydraulic hand pump shall provide
a minimum flow of 1.25 cubic inches per cycle (2 strokes) at 1500
psig.
3.4.9 Hydraulic fluid loss.  Hydraulic fluid loss shall not exceed
0.05 cc (1 drop) for a single powered raise/lower cycle and a
single manual raise/lower cycle.
The MCSK shall withstand
3.4.10 Environmental characteristics.
the following operating and storage environmental conditions.
The MCSK shall be capable of performing all
3.4.10.1 Operating.
of the requirements specified herein while exposed to the following
environnental conditions:
-54C (-65F) to +71C (+160F)
(a)  Temperature:
(b) Humidity:  Up to 95 percent with a temperature of
60C (140F), including condensation due to temperature changes
(c)  Vibration:  Levels and duration as specified in
MIL-STD-810, method 514.2, Procedure VIII.
(d)  Shock:  Levels and duration as specified in
MIL-STD-810, Method 516.2, Procedure II.
(e)  Salt fog:  Levels as specified in MIL-STD-810.
3.4.10.2 Storage.  The MCSK shall be able to withstand storage
in the following environmental conditions and be able to perform
as specified herein after such exposure: