| MIL-M-38510/108A
TABLE I. Electrical performance characteristics Continued.
Temperature
Device
Limits 1/
Unit
Conditions
Test
Symbol
range
type
Min
Max
TA = +25C
Fall time
See figure 2
01, 02
80
ns
tf
TA = -55C, +125C
125
TA = +25C
Channel
C.S.
See figure 3
01, 02
80
dB
separation
1/
Limits apply to each transistor within the array, unless otherwise specified.
2/
Does not apply to Q5 of device type 02.
3/
Applies only to Darlington pair (Q3, Q4) of device type 01.
4/
Applies only to differential pair (Q1, Q2) of device type 02.
5/
Does not apply to Darlington pair (Q3, Q4) of device type 01.
6/
Does not apply to differential pair (Q1, Q2) of device type 02.
7/
Applies for pairs (Q1, Q2) of device type 01 and for pairs (Q1, Q3), (Q1, Q4), (Q1, Q5) of device type 02.
(VBE @ 125C VBE @ 25C)/(125C - 25C), (VBE @ 25C VBE @ -55C)/(25C (-55C))
8/
(|VBEQA - VBEQB| @ 125C - |VBEQA - VBEQB| @ 25C)/(125C - 25C),
9/
(|VBEQA - VBEQB| @ 25C - |VBEQA - VBEQB| @ -55C)/(25C (-55C))
TABLE II. Electrical test requirements.
Subgroups (see table III)
MIL-PRF-38535
Class S
Class B
test requirements
devices
devices
Interim electrical parameters
1
1
1*, (2, 3, 4)**
Final electrical test parameters
1*, (2, 3, 4)**
Group A test requirements
1,2,3,4,5,6
1, 2, 3, 4
7,9,10,11
Group B electrical test parameters when
1,2,3 and
using the method 5005 QCI option
table IV delta
N/A
limits
1,2,3 and table
Group C end-point electrical
1,2,3 and
IV delta
parameters
table IV delta
limits
limits
Group D end-point electrical
1,2,3
1,2,3
parameters
*PDA applies to subgroup 1
** ĆVBE/ĆT and (Ć|VBEQA - VBEQB|)/ĆT test as specified in table III herein for group A, subgroups 2
and 3, and ft tests as specified in table III herein for group A, subgroup 4, are not required for
final electrical tests (for device 02 only) but shall be performed for group A sample testing.
4. VERIFICATION.
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or
as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not
effect the form, fit, or function as function as described herein.