| TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Cases
Limits
A,C,D
-
3
4
5
6
7
8
-
9
10
11
12
1
2
Measured
Note
Subgroup
Symbol
Case
terminal
Min
Max
Unit
M
NC
BQ2
EQ2
CQ2
BQ1
EQ1
CQ1
NC
BQ3
SUB
CQ3
CQ4
EQ4
BQ4/
Test no.
EQ3
7
GND
C.S.
145
CQ2
80
dB
1
TA =
+25C
"
9
146
CQ1
100
ns
2
td
TA =
+25C
"
147
CQ2
100
"
"
td
"
148
CQ1
50
"
"
tr
"
149
CQ2
50
"
"
tr
"
150
CQ1
200
"
"
ts
"
151
CQ2
200
"
"
ts
"
152
CQ1
80
"
"
tf
"
153
CQ2
80
"
"
tf
10
"
154
CQ1
160
"
"
td
TA =
+125C
"
155
CQ2
160
"
"
td
"
156
CQ1
80
"
"
tr
"
157
CQ2
80
"
"
tr
"
158
CQ1
300
"
"
ts
"
159
CQ2
300
"
"
ts
"
160
CQ1
125
"
"
tf
"
161
CQ2
125
"
"
tf
"
11
162
CQ1
160
"
"
td
TA = -55C
"
163
CQ2
160
"
"
td
"
164
CQ1
80
"
"
tr
"
165
CQ2
80
"
"
tr
"
166
CQ1
300
"
"
ts
"
167
CQ2
300
"
"
ts
"
168
CQ1
125
"
"
tf
"
169
CQ2
125
"
"
tf
NOTES:
1. See figure 3.
2. See figure 2.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |