| TABLE III. Group A inspection for device type 04 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
2
169
8.0 V
0V
350 mA
2.0
V
VIN(on)
OUT1
170
8.0 V
"
350 mA
"
"
OUT2
TA =
+125C
"
"
171
8.0 V
"
350 mA
OUT3
172
8.0 V
"
350 mA
"
"
OUT4
173
8.0 V
"
350 mA
"
"
OUT5
174
8.0 V
"
350 mA
"
"
OUT6
175
8.0 V
"
350 mA
"
"
OUT7
A
0V
COM
10.0
176
"
50 V
IR
177
"
"
0V
COM
"
"
178
"
"
0V
COM
"
"
179
"
"
0V
COM
"
"
180
"
"
0V
COM
"
"
181
"
"
0V
COM
"
"
182
"
"
0V
COM
"
"
183
0V
0V
350 mA
2.0
V
VF
OUT1
184
"
"
350 mA
"
"
OUT2
"
"
185
"
"
350 mA
OUT3
"
"
186
"
"
350 mA
OUT4
"
"
187
"
"
350 mA
OUT5
188
"
"
350 mA
"
"
OUT6
"
"
189
"
"
350 mA
OUT7
1000
3003
190
"
350 mA IB1-OUT1
hFE
IB1
"
191
"
350 mA
IB2-OUT2
IB2
"
350 mA
"
192
IB3-OUT3
IB3
"
193
"
350 mA
IB4-OUT4
IB4
"
350 mA
"
194
IB5-OUT5
IB5
"
195
"
350 mA
IB6-OUT6
IB6
196
"
"
350 mA
IB7
IB7-OUT7
A
3
10.0
197
0V
50 V
ICEX
OUT1
198
"
50 V
"
"
TA =
OUT2
-55C
"
"
199
"
50 V
OUT3
"
"
200
"
50 V
OUT4
"
"
201
"
50 V
OUT5
202
"
50 V
"
"
OUT6
203
"
50 V
"
"
OUT7
850 A
3007
204
"
350 mA
1.8
V
VCE(sat)
OUT1
850 A
"
350 mA
205
"
"
OUT2
850 A
"
"
"
350 mA
206
OUT3
850 A
"
350 mA
207
"
"
OUT4
850 A
"
350 mA
208
"
"
OUT5
850 A
"
350 mA
209
"
"
OUT6
850 A
"
350 mA
210
"
"
OUT7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |