| ![]() TABLE III. Group A inspection for device type 04 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
550 A
3
3007
211
0V
200 mA
1.5
V
VCE(sat)
OUT1
550 A
"
200 mA
212
"
"
OUT2
TA =
-55C
550 A
"
200 mA
"
"
213
OUT3
550 A
"
200 mA
214
"
"
OUT4
550 A
"
200 mA
215
"
"
OUT5
550 A
"
200 mA
216
"
"
OUT6
550 A
"
200 mA
217
"
"
OUT7
350 A
3007
218
"
100 mA
1.3
V
VCE(sat)
OUT1
350 A
"
100 mA
219
"
"
OUT2
350 A
"
100 mA
220
"
"
OUT3
350 A
"
100 mA
221
"
"
OUT4
350 A
"
"
"
100 mA
222
OUT5
350 A
"
100 mA
223
"
"
OUT6
350 A
"
"
"
100 mA
224
OUT7
A
225
5.0 V
"
250
500
IIN(on)
IN1
226
5.0 V
"
"
"
"
IN2
"
227
5.0 V
"
"
"
IN3
"
"
"
228
5.0 V
"
IN4
229
5.0 V
"
"
"
"
IN5
"
"
"
230
5.0 V
"
IN6
231
5.0 V
"
"
"
"
IN7
A
"
232
12.0 V
750
1450
IN1
IIN(on)
"
233
12.0 V
"
"
"
IN2
"
234
12.0 V
"
"
"
IN3
"
235
12.0 V
"
"
"
IN4
"
"
"
"
236
12.0 V
IN5
"
"
"
"
237
12.0 V
IN6
"
"
"
"
238
12.0 V
IN7
25 A
A
239
"
50 V
500
IIN(off)
OUT1
25 A
240
"
50V
"
"
OUT2
25 A
241
"
50 V
"
"
OUT3
25 A
242
"
50 V
"
"
OUT4
25 A
"
"
243
"
50 V
OUT5
25 A
244
"
50 V
"
"
OUT6
25 A
"
50 V
245
"
"
OUT7
246
6.0 V
0V
125 mA
2.0
V
VIN(on)
OUT1
247
6.0 V
"
125 mA
"
"
OUT2
248
6.0 V
"
125 mA
"
"
OUT3
"
"
249
6.0 V
"
125 mA
OUT4
"
"
250
6.0 V
"
125 mA
OUT5
251
6.0 V
"
125 mA
"
"
OUT6
"
"
252
6.0 V
"
125 mA
OUT7
|