| TABLE III. Group A inspection for device type 08 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup Symbol
STD- Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
883
no.
terminal
method
GND COM
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
25 A
A
1
0V
50 V
41
500
OUT1
IIN(off)
25 A
42
"
50V
"
"
TA =
OUT2
+25C
25 A
"
"
43
"
50 V
OUT3
25 A
44
"
50 V
"
"
OUT4
25 A
45
"
50 V
"
"
OUT5
25 A
46
"
50 V
"
"
OUT6
25 A
47
"
50 V
"
"
OUT7
25 A
48
"
50 V
"
"
OUT8
49
2.0 V
0V
200 mA
2.0
V
VIN(on)
OUT1
50
2.0 V
"
200 mA
"
"
OUT2
"
"
51
2.0 V
"
200 mA
OUT3
52
2.0 V
"
200 mA
"
"
OUT4
53
2.0 V
"
200 mA
"
"
OUT5
"
"
54
2.0 V
"
200 mA
OUT6
55
2.0 V
"
200 mA
"
"
OUT7
"
"
56
2.0 V
"
200 mA
OUT8
2.0
V
57
2.2 V
0V
250 mA
VIN(on)
OUT1
58
2.2 V
"
250 mA
"
"
OUT2
"
"
59
2.2 V
"
250 mA
OUT3
60
2.2 V
"
250 mA
"
"
OUT4
61
2.2 V
"
250 mA
"
"
OUT5
62
2.2 V
"
250 mA
"
"
OUT6
"
"
63
2.2 V
"
250 mA
OUT7
64
2.2 V
"
250 mA
"
"
OUT8
2.0
V
65
2.4 V
0V
300 mA
VIN(on)
OUT1
66
2.4 V
"
300 mA
"
"
OUT2
"
"
67
2.4 V
"
300 mA
OUT3
68
2.4 V
"
300 mA
"
"
OUT4
69
2.4 V
"
300 mA
"
"
OUT5
70
2.4 V
"
300 mA
"
"
OUT6
"
"
71
2.4 V
"
300 mA
OUT7
"
"
72
2.4 V
"
300 mA
OUT8
A
73
0V
50 V
0V
COM
10.0
IR
74
"
"
0V
COM
"
"
75
"
"
0V
COM
"
"
76
"
"
0V
COM
"
"
77
"
"
0V
COM
"
"
78
"
"
0V
COM
"
"
79
"
"
0V
COM
"
"
80
"
"
0V
COM
"
"
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |