| TABLE III. Group A inspection for device type 08 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup Symbol
STD- Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
883
no.
terminal
method
GND COM
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
1
81
0V
0V
350 mA
2.0
V
VF
OUT1
82
"
"
350 mA
"
"
OUT2
TA =
+25C
"
"
83
"
"
350 mA
OUT3
84
"
"
350 mA
"
"
OUT4
85
"
"
350 mA
"
"
OUT5
86
"
"
350 mA
"
"
OUT6
87
"
"
350 mA
"
"
OUT7
88
"
"
350 mA
"
"
OUT8
350 mA IB1-OUT1 1000
3003
89
"
hFE
IB1
"
90
"
350 mA
IB2-OUT2
IB2
"
350 mA
"
91
IB3-OUT3
IB3
"
92
"
350 mA
IB4-OUT4
IB4
"
93
"
350 mA
IB5-OUT5
IB5
"
350 mA
"
94
IB6-OUT6
IB6
"
95
"
350 mA
IB7-OUT7
IB7
"
350 mA
"
96
IB8-OUT8
IB8
A
2
10.0
97
0V
50 V
ICEX
OUT1
98
"
50 V
"
"
TA =
OUT2
+125C
"
"
99
"
50 V
OUT3
100
"
50 V
"
"
OUT4
101
"
50 V
"
"
OUT5
102
"
50 V
"
"
OUT6
"
"
103
"
50 V
OUT7
104
"
50 V
"
"
OUT8
500 A
1.8
V
3007
105
"
350 mA
VCE(sat)
OUT1
500 A
"
350 mA
106
"
"
OUT2
500 A
"
"
"
350 mA
107
OUT3
500 A
"
350 mA
108
"
"
OUT4
500 A
"
350 mA
109
"
"
OUT5
500 A
"
350 mA
110
"
"
OUT6
500 A
"
"
"
350 mA
111
OUT7
500 A
"
"
"
350 mA
112
OUT8
350 A
1.5
V
3007
113
"
200 mA
VCE(sat)
OUT1
350 A
"
200 mA
114
"
"
OUT2
350 A
"
"
"
200 mA
115
OUT3
350 A
"
200 mA
116
"
"
OUT4
350 A
"
200 mA
117
"
"
OUT5
350 A
"
200 mA
118
"
"
OUT6
350 A
"
200 mA
119
"
"
OUT7
350 A
"
200 mA
120
"
"
OUT8
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |