| TABLE III. Group A inspection for device type 08 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup Symbol
STD- Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
883
no.
terminal
method
GND COM
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
25 A
A
3
0V
50 V
233
500
OUT1
IIN(off)
25 A
234
"
50V
"
"
TA =
OUT2
-55C
25 A
"
"
235
"
50 V
OUT3
25 A
236
"
50 V
"
"
OUT4
25 A
237
"
50 V
"
"
OUT5
25 A
238
"
50 V
"
"
OUT6
25 A
239
"
50 V
"
"
OUT7
25 A
240
"
50 V
"
"
OUT8
241
2.6 V
0V
200 mA
2.0
V
VIN(on)
OUT1
242
2.6 V
"
200 mA
"
"
OUT2
"
"
243
2.6 V
"
200 mA
OUT3
244
2.6 V
"
200 mA
"
"
OUT4
245
2.6 V
"
200 mA
"
"
OUT5
"
"
246
2.6 V
"
200 mA
OUT6
247
2.6 V
"
200 mA
"
"
OUT7
"
"
248
2.6 V
"
200 mA
OUT8
2.0
V
249
2.8 V
0V
250 mA
VIN(on)
OUT1
250
2.8 V
"
250 mA
"
"
OUT2
"
"
251
2.8 V
"
250 mA
OUT3
252
2.8 V
"
250 mA
"
"
OUT4
253
2.8 V
"
250 mA
"
"
OUT5
254
2.8 V
"
250 mA
"
"
OUT6
"
"
255
2.8 V
"
250 mA
OUT7
256
2.8 V
"
250 mA
"
"
OUT8
2.0
V
257
3.0 V
0V
300 mA
VIN(on)
OUT1
258
3.0 V
"
300 mA
"
"
OUT2
"
"
259
3.0 V
"
300 mA
OUT3
260
3.0 V
"
300 mA
"
"
OUT4
261
3.0 V
"
300 mA
"
"
OUT5
262
3.0 V
"
300 mA
"
"
OUT6
"
"
263
3.0 V
"
300 mA
OUT7
"
"
264
3.0 V
"
300 mA
OUT8
A
265
0V
50 V
0V
COM
10.0
IR
266
"
"
0V
COM
"
"
267
"
"
0V
COM
"
"
268
"
"
0V
COM
"
"
269
"
"
0V
COM
"
"
270
"
"
0V
COM
"
"
271
"
"
0V
COM
"
"
272
"
0V
COM
"
"
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |