| TABLE III. Group A inspection for device type 08 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup Symbol
STD- Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
883
no.
terminal
method
GND COM
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
3
273
0V
0V
350 mA
2.0
V
VF
OUT1
274
"
"
350 mA
"
"
OUT2
TA =
-55C
"
"
275
"
"
350 mA
OUT3
276
"
"
350 mA
"
"
OUT4
277
"
"
350 mA
"
"
OUT5
278
"
"
350 mA
"
"
OUT6
279
"
"
350 mA
"
"
OUT7
280
"
"
350 mA
"
"
OUT8
500
3003
281
"
350 mA IB1-OUT1
hFE
IB1
"
282
"
350 mA
IB2-OUT2
IB2
"
350 mA
"
283
IB3-OUT3
IB3
"
284
"
350 mA
IB4-OUT4
IB4
"
285
"
350 mA
IB5-OUT5
IB5
"
350 mA
"
286
IB6-OUT6
IB6
"
287
"
350 mA
IB7-OUT7
IB7
"
350 mA
"
288
IB8-OUT8
IB8
ns
9
3003
289
"
OUT IN1-OUT1
750
tPLH
IN1
Fig. 4
"
"
290
"
OUT
TA =
IN2
IN2-OUT2
+25C
"
OUT
291
"
"
IN3-OUT3
IN3
"
"
292
"
OUT
IN4
IN4-OUT4
"
"
293
"
OUT
IN5
IN5-OUT5
"
"
294
"
OUT
IN6
IN6-OUT6
"
OUT
"
"
295
IN7-OUT7
IN7
"
"
296
"
OUT
IN8
IN8-OUT8
3003
297
"
OUT
300
ns
tPHL
IN1
IN1-OUT1
Fig. 4
"
"
298
"
OUT
IN2
IN2-OUT2
"
OUT
"
"
299
IN3-OUT3
IN3
"
"
300
"
OUT
IN4
IN4-OUT4
"
"
301
"
OUT
IN5
IN5-OUT5
"
"
302
"
OUT
IN6
IN6-OUT6
"
OUT
"
"
303
IN7-OUT7
IN7
"
OUT
"
"
304
IN8-OUT8
IN8
NOTE: Pins not designated are open.
|