| TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
MIL-
Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup Symbol STD-883
Meas.
Test No.
GND
G
A
B
C
W
Y
terminal Min
Max
Unit
D0
D1
D2
D3
D4
D5
D6
D7
VCC
method
3003
73
GND
5.0 V
GND
GND
IN
GND
GND
OUT
5.0 V
A to W
6
32
ns
9
tPHL1
"
(Fig 4)
74
"
5.0 V
"
"
GND
IN
GND
"
"
B to W
"
"
"
TC = 25C
"
"
"
75
"
5.0 V
"
"
GND
GND
IN
"
"
C to W
"
"
"
"
"
76
"
5.0 V
"
"
IN
GND
GND
"
"
A to W
"
29
"
tPLH1
"
"
"
77
"
5.0 V
"
"
GND
IN
GND
"
"
B to W
"
"
"
"
"
"
78
"
5.0 V
"
"
GND
GND
IN
"
"
C to W
"
"
"
"
"
79
"
5.0 V
"
"
IN
GND
GND
OUT
"
A to Y
"
40
"
tPHL2
"
"
"
80
"
5.0 V
"
"
GND
IN
GND
"
"
B to Y
"
"
"
"
"
"
81
"
5.0 V
"
"
GND
GND
IN
"
"
C to Y
"
"
"
"
"
"
82
"
5.0 V
"
"
IN
GND
GND
"
"
A to Y
"
39
tPLH2
"
"
"
83
"
5.0 V
"
"
GND
IN
GND
"
"
B to Y
"
"
"
"
"
"
84
"
5.0 V
"
"
GND
GND
IN
"
"
C to Y
"
"
"
"
"
85
5.0 V
"
IN
GND
GND
GND
OUT
"
G to W
6
28
"
tPHL3
"
"
86
"
"
"
"
"
"
OUT
"
G to W
6
24
"
tPLH3
"
"
87
"
"
"
"
"
"
OUT
"
G to Y
8
37
"
tPHL4
"
"
88
"
"
"
"
"
"
OUT
"
G to Y
8
35
"
tPLH4
3
20
"
"
89
IN
"
GND
GND
GND
GND
OUT
"
"
Do to W
tPHL5
"
"
"
"
"
"
90
IN
"
"
5.0 V
GND
"
"
"
D1 to W
"
"
"
"
"
91
IN
"
"
GND
5.0 V
"
"
"
"
D2 to W
"
"
"
"
"
92
IN
"
"
5.0 V
5.0 V
"
"
"
"
D3 to W
"
"
"
"
"
93
IN
"
"
GND
GND
5.0 V
"
"
"
D4 to W
"
"
"
"
"
94
IN
"
"
5.0 V
GND
"
"
"
"
D5 to W
"
"
"
"
"
95
IN
"
"
GND
5.0 V
"
"
"
"
D6 to W
"
"
"
"
"
96
"
IN
"
5.0 V
5.0 V
"
"
"
"
D7 to W
"
"
97
IN
"
"
GND
GND
GND
"
"
"
17
"
tPLH5
Do to W
"
"
"
"
98
IN
"
"
5.0 V
GND
"
"
"
"
"
D1 to W
"
"
"
"
99
IN
"
"
GND
5.0 V
"
"
"
"
"
D2 to W
"
"
"
"
100
IN
"
"
5.0 V
5.0 V
"
"
"
"
"
D3 to W
"
"
"
"
101
IN
"
"
GND
GND
5.0 V
"
"
"
"
D4 to W
"
"
"
"
102
IN
"
"
5.0 V
GND
"
"
"
"
"
D5 to W
"
"
"
"
103
IN
"
"
GND
5.0 V
"
"
"
"
"
D6 to W
"
"
"
"
104
"
IN
"
5.0 V
5.0 V
"
"
"
"
"
D7 to W
See note at end of device type 02.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |