| TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
MIL-
Subgroup
Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Symbol STD-883
Meas.
Test No.
GND
G
A
B
C
W
Y
VCC terminal Min
Max
Unit
D0
D1
D2
D3
D4
D5
D6
D7
method
9
105
IN
GND
GND
GND
GND
GND
OUT
5.0 V Do to Y
6
29
ns
3003
tPHL6
"
"
(Fig 4)
106
IN
"
"
5.0 V
GND
"
"
"
"
"
TC = 25C
D1 to Y
"
"
"
"
107
IN
"
"
GND
5.0 V
"
"
"
"
"
D2 to Y
"
"
"
"
108
IN
"
"
5.0 V
5.0 V
"
"
"
"
"
D3 to Y
"
"
"
"
109
IN
"
"
GND
GND
5.0 V
"
"
"
"
D4 to Y
D5 to Y
"
"
"
"
110
IN
"
"
5.0 V
GND
"
"
"
"
"
"
"
"
"
111
IN
"
"
GND
5.0 V
"
"
"
"
"
D6 to Y
"
"
"
"
112
"
IN
"
5.0 V
5.0 V
"
"
"
"
"
D7 to Y
"
113
IN
"
"
GND
GND
GND
"
"
6
29
"
"
tPLH6
Do to Y
"
"
"
"
114
IN
"
"
5.0 V
GND
"
"
"
"
"
D1 to Y
"
"
"
"
115
IN
"
"
GND
5.0 V
"
"
"
"
"
D2 to Y
"
"
"
"
116
IN
"
"
5.0 V
5.0 V
"
"
"
"
"
D3 to Y
"
"
"
"
117
IN
"
"
GND
GND
5.0 V
"
"
"
"
D4 to Y
"
"
"
"
118
IN
"
"
5.0 V
GND
"
"
"
"
"
D5 to Y
"
"
"
"
119
IN
"
"
GND
5.0 V
"
"
"
"
"
D6 to Y
"
"
"
"
"
120
"
IN
"
5.0 V
5.0 V
"
"
"
"
D7 to Y
10
121
GND
5.0 V
"
"
IN
GND
GND
OUT
"
A to W
6
40
"
"
tPHL1
"
"
122
"
5.0 V
"
"
GND
IN
GND
"
"
B to W
"
"
"
TC = 125C
"
"
"
123
"
5.0 V
"
"
GND
GND
IN
"
"
C to W
"
"
"
"
124
"
5.0 V
"
"
IN
GND
GND
"
"
A to W
"
38
"
"
tPLH1
"
"
"
125
"
5.0 V
"
"
GND
IN
GND
"
"
B to W
"
"
"
"
"
"
126
"
5.0 V
"
"
GND
GND
IN
"
"
C to W
"
"
"
"
127
"
5.0 V
"
"
IN
GND
GND
OUT
"
A to Y
8
49
"
"
tPHL2
"
"
"
128
"
5.0 V
"
"
GND
IN
GND
"
"
B to Y
"
"
"
"
"
"
129
"
5.0 V
"
"
GND
GND
IN
"
"
C to Y
"
"
"
"
130
"
5.0 V
"
"
IN
GND
GND
"
"
A to Y
"
45
"
"
tPLH2
"
"
"
131
"
5.0 V
"
"
GND
IN
GND
"
"
B to Y
"
"
"
"
"
"
132
"
5.0 V
"
"
GND
GND
IN
"
"
C to Y
"
"
"
"
133
5.0 V
"
IN
GND
GND
GND
OUT
"
G to W
6
37
"
"
tPHL3
"
"
134
"
"
"
"
"
"
OUT
"
G to W
6
35
"
tPLH3
"
"
135
"
"
"
"
"
"
OUT
"
G to Y
8
46
"
tPHL4
"
"
136
"
"
"
"
"
"
OUT
"
G to Y
8
42
"
tPLH4
"
137
IN
"
GND
GND
GND
GND
OUT
"
"
3
32
"
tPHL5
Do to W
"
"
"
"
138
IN
"
"
5.0 V
GND
"
"
"
"
"
D1 to W
"
"
"
"
139
IN
"
"
GND
5.0 V
"
"
"
"
"
D2 to W
"
"
"
"
140
IN
"
"
5.0 V
5.0 V
"
"
"
"
"
D3 to W
"
"
"
"
141
IN
"
"
GND
GND
5.0 V
"
"
"
"
D4 to W
"
"
"
"
142
IN
"
"
5.0 V
GND
"
"
"
"
"
D5 to W
"
"
"
"
143
IN
"
"
GND
5.0 V
"
"
"
"
"
D6 to W
"
"
"
"
144
"
IN
"
5.0 V
5.0 V
"
"
"
"
"
D7 to W
See note at end of device type 02.
|