| TABLE III. Group A inspection for device type 03.
Terminal conditions (pins not designated may be H > 2.0 V, or L < 0.8 V, or open).
MIL-
Case J, K, L, Z
1
2
3
4
5
6
7
8
9
10
11
12
Test limits
STD-883
Subgroup
Symbol
Meas.
Test No.
1D0
1Q0
1D1
1Q1
1D2
1Q2
1D3
1Q3
GND
Min
Max
Unit
method
terminal
1 MR
1E 0
1E 1
1
3006
1
4.5 V
0.8 V
0.8 V
4.5 V
-0.8 mA
4.5 V
4.5 V
4.5 V
GND
1Q0
2.4
V
VOH
"
2
"
"
"
"
"
-0.8 mA
"
"
"
1Q1
"
"
"
TC = 25C
"
"
3
"
"
"
"
"
"
-0.8 mA
"
"
1Q2
"
"
"
"
"
"
4
"
"
"
"
"
"
"
-0.8 mA
"
1Q3
"
"
"
"
"
5
"
"
"
"
"
"
"
"
2Q0
"
"
"
"
"
6
"
"
"
"
"
"
"
"
2Q1
"
"
"
"
"
7
"
"
"
"
"
"
"
"
2Q2
"
"
"
"
"
8
"
"
"
"
"
"
"
"
2Q3
"
"
"
3007
9
"
"
"
0.8 V
16 mA
0.8 V
0.8 V
0.8 V
"
1Q0
0.4
"
VOL
"
"
"
10
"
"
"
"
"
16 mA
"
"
"
1Q1
"
"
"
"
"
11
"
"
"
"
"
"
16 mA
"
"
1Q2
"
"
"
"
"
12
"
"
"
"
"
"
"
16 mA
"
1Q3
"
"
"
"
"
13
"
"
"
"
"
"
"
"
2Q0
"
"
"
"
"
14
"
"
"
"
"
"
"
"
2Q1
"
"
"
"
"
"
15
"
"
"
"
"
"
"
2Q2
"
"
"
"
"
16
"
"
"
"
"
"
"
"
2Q3
"
"
"
-1.5
"
17
-12 mA
"
VIC
1 MR
"
"
"
18
-12 mA
"
"
1E 0
"
"
19
-12 mA
"
"
"
1E 1
"
"
20
-12 mA
"
1D0
"
"
"
"
21
-12 mA
"
1D1
"
"
"
"
22
-12 mA
"
1D2
"
"
"
"
23
-12 mA
"
1D3
"
"
"
24
"
"
"
"
2 MR
"
"
25
"
"
"
2E 0
"
"
"
"
26
"
2E 1
"
"
27
"
2D0
"
"
"
"
28
"
2D1
"
"
"
"
29
"
2D2
"
"
"
"
30
"
2D3
"
"
"
3009
31 CKT A
GND
GND
0.4 V
"
1D0
-0.7
-2.4
mA
IIL1
"
"
"
31 CKT B
"
"
"
"
1D0
-0.7
-1.6
"
"
"
"
31 CKT C
"
"
"
"
1D0
-0.5
-1.4
"
"
"
"
32 CKT A
"
"
0.4 V
"
1D1
-0.7
-2.4
"
"
"
"
32 CKT B
"
"
"
"
1D1
-0.7
-1.6
"
"
"
"
32 CKT C
"
"
"
"
1D1
-0.5
-1.4
"
"
"
"
33 CKT A
"
"
0.4 V
"
1D2
-0.7
-2.4
"
"
"
"
33 CKT B
"
"
"
"
1D2
-0.7
-1.6
"
"
"
"
33 CKT C
"
"
"
"
1D2
-0.5
-1.4
"
"
"
"
34 CKT A
"
"
0.4 V
"
1D3
-0.7
-2.4
"
"
"
"
34 CKT B
"
"
"
"
1D3
-0.7
-1.6
"
"
"
"
34 CKT C
"
"
"
"
1D3
-0.5
-1.4
"
"
"
"
35 CKT A
"
2D0
-0.7
-2.4
"
"
"
"
35 CKT B
"
2D0
-0.7
-1.6
"
"
"
"
35 CKT C
"
2D0
-0.5
-1.4
"
"
"
"
36 CKT A
"
2D1
-0.7
-2.4
"
"
"
"
36 CKT B
"
2D1
-0.7
-1.6
"
"
"
"
36 CKT C
"
2D1
-0.5
-1.4
"
|