| TABLE III. Group A inspection for device type 01.
Terminal conditions (pins not designated may be high ≥ 2.0 V; or low ≤ 0.8 V; or open).
Subgroup
Symbol MIL-STD-
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Measured
Test limits
Unit
883
A, B, C, D
terminal
method
Test no.
1A
1B
1Y
2A
2B
2Y
GND
3Y
3A
3B
4Y
4A
4B
Min
Max
VCC
-800 A
1
3006
1
2.0 V
GND
GND
4.5 V
1Y
2.4
V
VOH
-800 A
"
2
GND
2.0 V
"
"
1Y
"
"
TA = 25C
-800 A
"
3
2.0 V
GND
"
"
2Y
"
"
-800 A
"
4
GND
2.0 V
"
"
2Y
"
"
-800 A
"
5
"
2.0 V
GND
"
3Y
"
"
-800 A
"
6
"
GND
2.0 V
"
3Y
"
"
-800 A
"
7
"
2.0 V
GND
"
4Y
"
"
-800 A
"
8
"
GND
2.0 V
"
4Y
"
"
3007
9
0.8 V
0.8 V
16 mA
"
"
1Y
0.4
V
VOH
"
10
0.8 V
0.8 V
16 mA
"
"
2Y
"
"
"
11
"
16 mA
0.8 V
0.8 V
"
3Y
"
"
"
12
"
16 mA
0.8 V
0.8 V
"
4Y
"
"
13
-12 mA
"
"
1A
-1.5
V
VIC
14
-12 mA
"
"
1B
"
"
15
-12 mA
"
"
2A
"
"
16
-12 mA
"
"
2B
"
"
17
"
-12 mA
"
3A
"
"
18
"
-12 mA
"
3B
"
"
19
"
-12 mA
"
4A
"
"
20
"
-12 mA
"
4B
"
"
A
3010
21
2.4 V
GND
"
5.5 V
1A
40
IIH1
"
22
GND
2.4 V
"
"
1B
"
"
"
23
2.4 V
GND
"
"
2A
"
"
"
24
GND
2.4 V
"
"
2B
"
"
"
25
"
2.4 V
GND
"
3A
"
"
"
26
"
GND
2.4 V
"
3B
"
"
"
27
"
2.4 V
GND
"
4A
"
"
"
28
"
GND
2.4 V
"
4B
"
"
A
3010
29
5.5 V
GND
"
"
1A
100
IIH2
"
30
GND
5.5 V
"
"
1B
"
"
"
31
5.5 V
GND
"
"
2A
"
"
"
32
GND
5.5 V
"
"
2B
"
"
"
33
"
5.5 V
GND
"
3A
"
"
"
34
"
GND
5.5 V
"
3B
"
"
"
35
"
5.5 V
GND
"
4A
"
"
"
36
"
GND
5.5 V
"
4B
"
"
3009
37
0.4 V
5.5 V
"
"
1A
-0.7
-1.6
mA
IIL
"
38
5.5 V
0.4 V
"
"
1B
"
"
"
"
39
0.4 V
5.5 V
"
"
2A
"
"
"
"
40
5.5 V
0.4 V
"
"
2B
"
"
"
"
41
"
0.4 V
5.5 V
"
3A
"
"
"
"
42
"
5.5 V
0.4 V
"
3B
"
"
"
"
43
"
0.4 V
5.5 V
"
4A
"
"
"
"
44
"
5.5 V
0.4 V
"
4B
"
"
"
See note at end of device type 01.
|