| ![]() MIL-M-38510/207E
TABLE IVG. Programming characteristics for circuit G.
Limits 1/
Unit
Parameter
Symbol
Conditions
Min
Recommended
Max
Required VCC for
VCCP
10.0
10.5
11.0
V
programming
ICCP
750
mA
ICC during programming
VCC = 11 V
Required output voltage
10.0
10.5
11.0
V
VOP
for programming
Output current while
IOP
20
mA
VOUT = 11 V
programming
Rate of voltage change
V/μs
1.0
10.0
IRR
of VCC or output
Programming pulse
μs
9
10
11
PWE
width (enabled)
Required VCC for
VCCV
3.8
4.0
4.2
V
verification
Maximum duty cycle for
MDC
25
25
%
VCC at VCCP
Address set-up time
100
ns
t1
μs
2/
5
VCCP set-up time
t2
100
ns
VCCP hold time
t5
100
ns
VOP set-up time
t3
100
ns
VOP hold time
t4
1/ TC = +25C.
2/ VCCP set-up time may be greater than 0 if VCCP rises at the same rate or faster than VOP.
31
|