| TABLE III. Group A inspection for device type 02. 1/
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Subgroup
Symbol
MIL-
A,B,D
Test limits
Measured
Unit
STD-883
terminal
Case C
9
12
13
14
2
1
3
4
5
6
7
8
10
11
Min
Max
method
Test no.
K1
Clock
Preset
VCC
Clear
NC
J1
J2
J3
GND
Q
K2
K3
Q
-100A
0.7 V
0.7 V
Q
2.4
V
1
VOH
3006
1
0.7 V
A
4.5 V
4.5 V 4.5 V
2.0 V
2.0 V
2.0 V
GND
TC = +25C
-100A
2.0 V
2.0 V
"
"
2
2.0 V
A
4.5 V
"
4.5 V
0.7 V
0.7 V
0.7 V
"
Q
4.5 V
4.5 V
"
"
"
3
4.5 V
4.5 V
0.7 V
"
2.0 V
4.5 V
4.5 V
4.5 V
Q
-100A
4.5 V
4.5 V
Q
"
"
4
4.5 V
4.5 V
2.0 V
"
0.7 V
4.5 V
4.5 V
4.5 V
"
-100A
0.3
"
VOL
3007
5
2.0 V
A
4.5 V
"
4.5 V
0.7 V
0.7 V
0.7 V
"
2 mA
2.0 V
2.0 V
Q
"
"
6
0.7 V
A
4.5 V
"
4.5 V
2.0 V
2.0 V
2.0 V
2 mA
"
0.7 V
0.7 V
Q
Q
"
"
7
4.5 V
4.5 V
0.7 V
"
2.0 V
4.5 V
4.5 V
2 mA
"
4.5 V
4.5 V
Q
"
"
8
4.5 V
"
2.0 V
"
0.7 V
4.5 V
"
"
2 mA
4.5 V
4.5 V
A
IIL1
3009
9
"
5.5 V
B
0.3 V
"
4.5 V
"
J1
-43
-140
10
"
"
"
4.5 V
0.3 V
4.5 V
"
J2
"
"
"
11
"
"
"
4.5 V
4.5 V
0.3 V
"
J3
"
"
"
12
0.3 V
"
B
"
"
4.5 V
4.5 V
K1
"
"
"
13
4.5 V
"
"
"
"
0.3 V
4.5 V
K2
"
"
"
14
"
"
"
"
"
4.5 V
0.3 V
K3
"
"
"
15
"
0.3 V
"
"
4.5 V
4.5 V
4.5 V
"
"
4.5 V
Clock
-105
-360
"
IIL2
16
"
0.3 V
"
B
"
"
"
"
"
"
Clock
-105
-360
"
17
`
0.3 V
"
"
"
"
"
"
"
Preset
-86
-280
"
18
"
"
0.3 V
"
"
"
"
"
"
Clear
-86
-280
"
GND
2.4 V
GND
GND
"
J1
10
"
IIH1
3010
19
GND
"
J2
"
"
20
"
"
"
GND
2.4 V
GND
"
J3
"
"
21
"
"
"
GND
GND
2.4 V
"
"
GND
GND
K1
"
"
22
2.4 V
"
GND
"
"
"
2.4 V
GND
K2
"
"
23
GND
"
"
"
"
"
"
GND
2.4 V
K3
"
"
24
GND
IIH2
25
"
"
GND
5.5 V
GND
GND
"
J1
100
"
26
"
"
"
GND
5.5 V
GND
"
J2
"
"
27
"
"
"
GND
GND
5.5 V
"
J3
"
"
28
5.5 V
"
GND
"
"
GND
GND
K1
"
"
29
GND
"
"
"
"
5.5 V
GND
K2
"
"
30
GND
"
"
"
"
GND
5.5 V
K3
"
"
IIH3
31
"
"
2.4 V
GND
GND
GND
GND
"
Clear
20
"
IIH3
32
GND
"
2.4 V
"
"
GND
GND
GND
Preset
20
"
IIH4
33
GND
"
5.5 V
"
GND
"
GND
GND
GND
Preset
200
"
34
"
"
5.5 V
GND
GND
"
GND
"
Clear
"
"
35
GND
5.5 V
GND
"
"
"
"
"
GND
GND
Clock
"
"
36
"
5.5 V
"
GND
"
"
"
"
"
"
Clock
"
"
37
"
2.4 V
GND
"
"
"
"
"
"
"
Clock
0
-200
"
IIH10
38
"
2.4 V
"
GND
"
"
"
"
"
"
Clock
0
-200
"
IIH10
IOS
3011
39
4.5 V
GND
GND
"
4.5 V
4.5 V
4.5 V
"
GND
4.5 V
4.5 V
Q
-3
-15
mA
IOS
3011
40
4.5 V
"
"
GND
4.5 V
4.5 V
4.5 V
GND
"
4.5 V
4.5 V
Q
-3
-15
"
ICC
3005
41 CKT A
GND
"
GND
"
4.5 V
GND
GND
GND
"
GND
GND
VCC
1.90
"
41 CKT B
"
"
GND
"
4.5 V
"
"
"
"
"
"
"
1.44
"
42 CKT A
"
"
4.5 V
"
GND
"
"
"
"
"
"
"
1.90
"
42 CKT B
"
"
4.5 V
"
GND
"
"
"
"
"
"
"
1.44
"
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125C.
2
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55C.
3
See footnotes at end of device type 02.
|