| TABLE III. Group A inspection for device types 03 Continued.
Terminal conditions (pins not designated may be high ≥2.1 V or low ≤0.8 V, or open or GND)
Subgroup
Symbol
MIL-STD-
Case E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Meas.
883
Test No.
Min
Max
Unit
A0
A1
A2
A3
A4
Q
GND
A5
A6
A7
A8
A9
DIN
VCC
CS
WE
method
terminal
7
Functional
GND
3014
43
3/
3/
3/
3/
3/
3/
3/
3/
3/
3/
3/
3/
3/
3/
3/
Q
3/
TC = 25C
tests
8
Same tests, terminal conditions, and limits as subgroup 7, except TC = 125C and -55C.
9
GALPAT
tAVQV
44
4/
4/
4/
4/
4/
4/
5/
GND
4/
4/
4/
4/
4/
4/
4/
4/
Q
70
ns
TC = 25C
Fig. 5
tSVQV
"
45
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
45
"
tSCQZ
"
46
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
50
"
tWLQZ
"
47
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
45
"
tWHQV
"
48
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
55
"
GGII
tWLWH
49
6/
6/
6/
6/
6/
6/
"
"
6/
6/
6/
6/
6/
6/
6/
6/
"
50
"
Fig. 5
tWHDC
"
50
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
10
"
tDCWL
"
51
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
10
"
tAVWL
"
52
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
10
"
tWHAC
"
53
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
10
"
"
tSVWL
"
54
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
10
"
tWHSC
"
55
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
10
"
Same tests, terminal conditions, and limits as for subgroup 9, except TC = 125C.
10
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55C.
11
See footnotes at end of table.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |