| TABLE III. Group A inspection for device type 11 - Continued
Terminal conditions (pins not designated may be high ≥2.1 V or low ≤0.8 V, or open or GND)
Subgroup
Symbol
MIL-STD-
Case W
1
2
3
4
5
6
7
8
9
10
11
Test limits
883
Meas.
Case X and K
1
2
3
4
5
6
7
8
9
10
11
method
terminal
Case Y
1
2
3
4
5
7
8
9
10
11
12
Test No.
A3
A2
A1
A0
A5
A6
A7
GND
D1
Q1
D2
Min
Max
Unit
1
VOL
3007
53
GND
GND
8 mA
GND
Q1
.45
V
TC = 25C
54
"
"
GND
"
Q2
"
"
55
"
"
GND
"
Q3
"
"
56
"
"
GND
"
Q4
"
"
ICC
3005
57
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
VCC
1/
mA
2
Same tests, terminal conditions, and limits as subgroup 1, except TC = 125C.
3
Same tests, terminal conditions, and limits as subgroup 1, except TC = -55C, and ICC (max) limit = 90 mA.
7
Functional
3014
58
3/
3/
3/
3/
3/
3/
GND
3/
3/
3/
Q
TC = 25C
tests
Same tests, terminal conditions, and limits as subgroup 7, except TC = 125C and -55C.
8
9
tAVQV
Fig. 5
59
4/
4/
4/
4/
4/
4/
4/
GND
4/
5/
4/
Q
75
ns
TC = 25C
tSVQV
60
"
"
"
"
"
"
"
"
"
"
"
"
45
"
tSCQZ
61
"
"
"
"
"
"
"
"
"
"
"
"
45
"
tWLQV
62
"
"
"
"
"
"
"
"
"
"
"
"
45
"
tWHQV
63
"
"
"
"
"
"
"
"
"
"
"
"
50
"
tWLWH
64
6/
6/
6/
6/
6/
6/
6/
"
6/
"
6/
"
55
"
tWHDC
65
"
"
"
"
"
"
"
"
"
"
"
"
5
"
tDCWL
66
"
"
"
"
"
"
"
"
"
"
"
"
5
"
tAVWL
67
"
"
"
"
"
"
"
"
"
"
"
"
10
"
tWHAC
68
"
"
"
"
"
"
"
"
"
"
"
"
10
"
tSVWL
69
"
"
"
"
"
"
"
"
"
"
"
"
5
"
tWHSC
70
"
"
"
"
"
"
"
"
"
"
"
"
5
"
Same tests, terminal conditions, and limits as subgroup 9, except TC = 125C.
10
Same tests, terminal conditions, and limits as subgroup 9, except TC = -55C.
11
See footnotes at end of table.
|