|
| TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
1
2
3
4
5
6
7
8
9
10
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
Test No.
A6
A5
A4
A3
A0
A1
A2
VSS
Min
Max
Min
Max
Min
Max
CE
W
A
IIH2
3010
49
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
A9
1.0
1.0
50
"
"
"
"
"
"
"
"
"
"
A8
"
"
"
51
"
"
"
"
"
"
"
"
"
"
A7
"
"
"
All inputs
IIL1 4/
3009
52
"
"
"
"
"
"
"
"
"
"
-1.0
"
together
IIL2
3009
53
GND
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
A6
-1.0
-1.0
"
54
5.5 V
GND
"
"
"
"
"
"
"
"
A5
"
"
"
55
"
5.5 V
GND
"
"
"
"
"
"
"
A4
"
"
"
56
"
"
5.5 V
GND
"
"
"
"
"
"
A3
"
"
"
57
"
"
"
5.5 V
GND
"
"
"
"
"
A0
"
"
"
58
"
"
"
"
5.5 V
GND
"
"
"
"
A1
"
"
"
59
"
"
"
"
"
5.5 V
GND
"
"
"
A2
"
"
"
60
"
"
"
"
"
"
5.5 V
GND
"
"
"
"
"
CE
61
"
"
"
"
"
"
"
5.5 V
"
GND
"
"
"
W
62
"
"
"
"
"
"
"
"
"
5.5 V
D3/Q3
"
"
"
63
"
"
"
"
"
"
"
"
"
"
D2/Q2
"
"
"
64
"
"
"
"
"
"
"
"
"
"
D1/Q1
"
"
"
65
"
"
"
"
"
"
"
"
"
"
D0/Q0
"
"
"
66
"
"
"
"
"
"
"
"
"
"
A9
"
"
"
67
"
"
"
"
"
"
"
"
"
"
A8
"
"
"
68
"
"
"
"
"
"
"
"
"
"
A7
"
"
"
IOHZ
69
GND
GND
GND
GND
GND
GND
GND
5.5 V
"
"
Q3/Q3
1.0
1.0
1.0
"
70
"
"
"
"
"
"
"
"
"
"
Q2/Q2
"
"
"
"
71
"
"
"
"
"
"
"
"
"
"
Q1/Q1
"
"
"
"
72
"
"
"
"
"
"
"
"
"
"
Q0/Q0
"
"
"
"
73
"
"
"
"
"
"
"
GND
"
0.8 V
Q3/Q3
"
"
"
"
74
"
"
"
"
"
"
"
"
"
"
Q2/Q2
"
"
"
"
75
"
"
"
"
"
"
"
"
"
"
Q1/Q1
"
"
"
"
76
"
"
"
"
"
"
"
"
"
"
Q0/Q0
"
"
"
"
IOLZ
77
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
Q3/Q3
-1.0
-1.0
-1.0
"
78
"
"
"
"
"
"
"
"
"
"
Q2/Q2
"
"
"
"
79
"
"
"
"
"
"
"
"
"
"
Q1/Q1
"
"
"
"
80
"
"
"
"
"
"
"
"
"
"
Q0/Q0
"
"
"
"
81
"
"
"
"
"
"
"
GND
"
0.8 V
Q3/Q3
"
"
"
"
82
"
"
"
"
"
"
"
"
"
"
Q2/Q2
"
"
"
"
83
"
"
"
"
"
"
"
"
"
"
Q1/Q1
"
"
"
"
84
"
"
"
"
"
"
"
"
"
"
Q0/Q0
"
"
"
"
IDD1
3005
85
GND
GND
GND
GND
GND
GND
GND
"
"
GND
VDD 5/
50
50
50
"
IDD2
86
"
"
"
"
"
"
"
"
"
"
VDD 6/
"
"
"
"
IDD3
87
"
"
"
"
"
"
"
"
"
"
VDD 7/
"
"
"
"
IDD4
88
"
"
"
"
"
"
"
"
"
"
VDD 13/
"
"
"
"
Subgroup 4
TC = +25C
Min
Max
Each
CI
3012
89
8/
8/
8/
8/
8/
8/
8/
GND
8/
8
pF
input
See footnotes at end of table III.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |