TABLE III. Group A inspection for device type 03.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
1
2
3
4
5
6
7
8
9
10
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
K
2
3
4
5
7
8
9
11
12
13
Test No.
A0
A1
A2
A3
A4
A5
Q
VSS
Min
Max
Min
Max
Min
Max
CE
W
50 A
VIC (POS)
1
A0
0.1
2.0
V
50 A
2
A1
"
"
"
50 A
3
A2
"
"
"
50 A
4
A3
"
"
"
50 A
5
A4
"
"
"
50 A
6
A5
"
"
"
50 A
7
"
"
"
W
50 A
8
"
"
"
CE
9
D
"
"
"
10
A11
"
"
"
11
A10
"
"
"
12
A9
"
"
"
13
A8
"
"
"
14
A7
"
"
"
15
A6
"
"
"
-50 A
VIC (NEG)
16
GND
A0
-0.1
-2.0
"
-50 A
17
"
A1
"
"
"
-50 A
18
"
A2
"
"
"
-50 A
19
"
A3
"
"
"
-50 A
20
"
A4
"
"
"
-50 A
21
"
A5
"
"
"
-50 A
"
22
"
"
"
W
-50 A
23
"
"
"
"
CE
24
"
D
"
"
"
25
"
A11
"
"
"
26
"
A10
"
"
"
27
"
A9
"
"
"
28
"
A8
"
"
"
29
"
A7
"
"
"
30
"
A6
"
"
"
"
VOL
3007
31
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
2/
4.5 V
GND
Q
0.4
0.4
0.4
"
"
VOH
3006
32
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
3/
4.5 V
GND
Q
2.4
2.4
2.4
"
See footnotes at end of table III.