| TABLE III. Group A inspection for device type 03 Continued.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
1
2
3
4
5
6
7
8
9
10
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
K
2
3
4
5
7
8
9
11
12
13
Test No.
A0
A1
A2
A3
A4
A5
Q
VSS
Min
Max
Min
Max
Min
Max
CE
W
A
IIH
3010
33
5.5 V
GND
GND
GND
GND
GND
GND
GND
GND
A0
1.0
34
GND
5.5 V
GND
"
"
"
"
"
"
A1
"
"
35
"
GND
5.5 V
"
"
"
"
"
"
A2
"
"
36
"
"
GND
5.5 V
"
"
"
"
"
A3
"
"
37
"
"
"
GND
5.5 V
"
"
"
"
A4
"
"
38
"
"
"
"
GND
5.5 V
"
"
"
A5
"
"
39
"
"
"
"
"
GND
5.5 V
"
"
"
"
W
40
"
"
"
"
"
"
GND
"
5.5 V
"
"
CE
41
"
"
"
"
"
"
"
"
GND
D
"
"
42
"
"
"
"
"
"
"
"
"
A11
"
"
43
"
"
"
"
"
"
"
"
"
A10
"
"
44
"
"
"
"
"
"
"
"
"
A9
"
"
45
"
"
"
"
"
"
"
"
"
A8
"
"
46
"
"
"
"
"
"
"
"
"
A7
"
"
47
"
"
"
"
"
"
"
"
"
A6
"
"
IIL
3009
48
GND
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
A0
-1.0
"
49
5.5 V
GND
5.5 V
"
"
"
"
"
"
A1
"
"
50
"
5.5 V
GND
"
"
"
"
"
"
A2
"
"
51
"
"
5.5 V
GND
"
"
"
"
"
A3
"
"
52
"
"
"
5.5 V
GND
"
"
"
"
A4
"
"
53
"
"
"
"
5.5 V
GND
"
"
"
A5
"
"
54
"
"
"
"
"
5.5 V
GND
"
"
"
"
W
55
"
"
"
"
"
"
5.5 V
"
GND
"
"
CE
56
"
"
"
"
"
"
"
"
5.5 V
D
"
"
57
"
"
"
"
"
"
"
"
"
A11
"
"
58
"
"
"
"
"
"
"
"
"
A10
"
"
59
"
"
"
"
"
"
"
"
"
A9
"
"
60
"
"
"
"
"
"
"
"
"
A8
"
"
61
"
"
"
"
"
"
"
"
"
A7
"
"
62
"
"
"
"
"
"
"
"
"
A6
"
"
IOHZ
63
GND
GND
GND
GND
GND
GND
5.5 V
"
"
"
Q
10
10
10
"
64
GND
GND
GND
GND
GND
GND
5.5 V
GND
"
GND
Q
10
10
10
"
IOLZ
65
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
GND
5.5 V
"
5.5 V
Q
-10
-10
-10
"
66
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
GND
GND
"
GND
Q
-10
-10
-10
"
See footnotes at end of table III.
|