| TABLE III. Group A inspection for device type 04.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
1
2
3
4
5
6
7
8
9
10
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
K
2
3
4
5
7
8
9
11
12
13
Test No.
A6
A5
A4
A3
A0
A1
A2
VSS
Min
Max
Min
Max
Min
Max
CE
W
50 A
VIC (POS)
1
A6
0.1
2.0
V
50 A
2
A5
"
"
"
50 A
3
A4
"
"
"
50 A
4
A3
"
"
"
50 A
5
A0
"
"
"
50 A
6
A1
"
"
"
50 A
7
A2
"
"
"
50 A
8
"
"
"
CE
50 A
9
"
"
"
W
10
D3/Q3
"
"
"
11
D2/Q2
"
"
"
12
D1/Q1
"
"
"
13
D0/Q0
"
"
"
14
A9
"
"
"
15
A8
"
"
"
16
A7
"
"
"
-50 A
VIC (NEG)
17
GND
A6
-0.1
-2.0
"
-50 A
18
"
A5
"
"
"
-50 A
19
"
A4
"
"
"
-50 A
20
"
A3
"
"
"
-50 A
21
"
A0
"
"
"
-50 A
22
"
A1
"
"
"
-50 A
23
"
A2
"
"
"
-50 A
24
"
"
"
"
CE
-50 A
"
25
"
"
"
W
26
"
D3/Q3
"
"
"
27
"
D2/Q2
"
"
"
28
"
D1/Q1
"
"
"
29
"
D0/Q0
"
"
"
30
"
A9
"
"
"
31
"
A8
"
"
32
"
A7
"
"
"
VOL
3007
33
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
GND
4.5 V
Q3 Q0
0.4
0.4
0.4
"
"
VOH
3006
34
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
GND
4.5 V
Q3 Q0
2.4
2.4
2.4
"
"
All
A
IIH1 4/
3010
35
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
1.0
inputs
together
See footnotes at end of table III.
|