Page Title: Table 3. Group A inspection for device type 05-cont.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
method
terminal
11
12
13
14
15
16
17
18
Subgroup 8
TC = +25C
K
15
16
17
18
21
22
23
24
Test No.
D
A11
A10
A9
A8
A7
A6
VDD
Min
Max
Min
Max
Min
Max
A
ICCDR
9/
72
9/
9/
9/
9/
9/
9/
9/
9/
VDD
400
PWR
73
9/
9/
9/
9/
9/
9/
9/
9/
VDD
2.5
V
DWN
Func-
15/
74
10/
10/
10/
10/
10/
10/
10/
10/
Q
10/
10/
V
tional
tests
Subgroup 9
Subgroup 10
Subgroup 11
TC = +25C
TC = +125C
TC = -55C
Min
Max
Min
Max
Min
Max
tAVQV
Fig. 4
75
11/
11/
11/
11/
11/
11/
11/
4.75 V
Q
200
250
200
ns
15/
tELQV
76
11/
11/
11/
11/
11/
11/
11/
4.75 V
Q
220
280
220
ns
Subgroup 12
TC = +25C
Min
Max
IDDOP
77
12/
12/
12/
12/
12/
12/
12/
5.25 V
VDD
4.5
mA
See footnotes at end of table III.