| TABLE III. Group A inspection for device type 06 Continued.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
1
2
3
4
5
6
7
8
9
10
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
K
2
3
4
5
7
8
9
11
12
13
Test No.
A6
A5
A4
A3
A0
A1
A2
VSS
Min
Max
Min
Max
Min
Max
CE
W
All
A
IIH1 4/
3010
35
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
GND
5.25 V
32
160
inputs
together
IIH2
36
5.25 V
GND
GND
GND
GND
GND
GND
GND
"
GND
A6
2.0
10
"
37
GND
5.25 V
GND
"
"
"
"
"
"
"
A5
"
"
"
38
"
GND
5.25 V
"
"
"
"
"
"
"
A4
"
"
"
39
"
"
GND
5.25 V
"
"
"
"
"
"
A3
"
"
"
40
"
"
"
GND
5.25 V
"
"
"
"
"
A0
"
"
"
41
"
"
"
"
GND
5.25 V
"
"
"
"
A1
"
"
"
42
"
"
"
"
"
GND
5.25 V
"
"
"
A2
"
"
"
43
"
"
"
"
"
"
GND
5.25 V
"
"
"
"
"
CE
44
"
"
"
"
"
"
"
GND
"
5.25 V
"
"
"
W
45
"
"
"
"
"
"
"
"
"
GND
"
"
"
D3/Q3
46
"
"
"
"
"
"
"
"
"
"
"
"
"
D2/Q2
47
"
"
"
"
"
"
"
"
"
"
"
"
"
D1/Q1
48
"
"
"
"
"
"
"
"
"
"
"
"
"
D0/Q0
49
"
"
"
"
"
"
"
"
"
"
A9
"
"
"
50
"
"
"
"
"
"
"
"
"
"
A8
"
"
"
51
"
"
"
"
"
"
"
"
"
"
A7
"
"
"
All
"
IIL1 4/
3009
52
"
"
"
"
"
"
"
"
"
"
-32
-160
inputs
together
IIL2
53
GND
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
5.25 V
"
5.25 V
A6
-2.0
-10
"
54
5.25 V
GND
5.25 V
"
"
"
"
"
"
"
A5
"
"
"
55
"
5.25 V
GND
"
"
"
"
"
"
"
A4
"
"
"
56
"
"
5.25 V
GND
"
"
"
"
"
"
A3
"
"
"
57
"
"
"
5.25 V
GND
"
"
"
"
"
A0
"
"
"
58
"
"
"
"
5.25 V
GND
"
"
"
"
A1
"
"
"
59
"
"
"
"
"
5.25 V
GND
"
"
"
A2
"
"
"
60
"
"
"
"
"
"
5.25 V
GND
"
"
"
"
"
CE
"
"
"
61
"
"
"
"
"
"
"
5.25 V
"
GND
W
62
"
"
"
"
"
"
"
"
"
5.25 V
"
"
"
D3/Q3
63
"
"
"
"
"
"
"
"
"
"
"
"
D2/Q2
64
"
"
"
"
"
"
"
"
"
"
"
"
D1/Q1
"
"
"
65
"
"
"
"
"
"
"
"
"
D0/Q0
66
"
"
"
"
"
"
"
"
"
A9
"
"
"
67
"
"
"
"
"
"
"
"
"
A8
"
"
"
68
"
"
"
"
"
"
"
"
"
A7
"
"
"
See footnotes at end of table III.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |