MIL-M-38510/2G
2.2 Government documents.
2.2.1 Specifications and Standards. The following specifications and standards form a part of this
specification to the extent specified herein. Unless otherwise specified, the issues of these documents are
those cited in the solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-38535 -
Integrated Circuits (Microcircuits) Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883
-
Test Method Standard for Microelectronics.
MIL-STD-1835
-
Interface Standard Electronic Component Case Outlines
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or
http://assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D,
Philadelphia, PA 19111-5094.)
2.3 Order of precedence. In the event of a conflict between the text of this specification and the references
cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes
applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Qualification. Microcircuits furnished under this specification shall be products that are manufactured by
a manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturers list before
contract award (see 4.3 and 6.3).
3.2 Item requirements.  The individual item requirements shall be in accordance with MIL-PRF-38535 and
as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The
modification in the QM plan shall not affect the form, fit, or function as described herein.
3.3 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall
be as specified in MIL-PRF-38535 and herein.
3.3.1 Terminal connections and logic diagrams. The terminal connections and logic diagrams shall be as
specified on figures 1.
3.3.2 Truth tables and logic equations. The truth tables and logic equations shall be as specified on figure 2.
3.3.3 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available
to the qualifying activity and the preparing activity (DSCC-VAS) upon request.
3.3.4 Case outlines. The case outlines shall be as specified in 1.2.3.
3.4 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see
6.6).
3.5 Electrical performance characteristics. The electrical performance characteristics are as specified in
table I, and apply over the full recommended case operating temperature range, unless otherwise specified.
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the
subgroups specified in table II. The electrical tests for each subgroup are described in table III. Subgroups 7
and 8 testing requires only a summary of attributes data.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.