| MIL-M-38510/2G
NOTES:
1. Clear or preset inputs dominate regardless of the state of clock or J-K inputs.
2. Clear or preset input pulse characteristics: Vgen = 3 V, t0 = t1 = 10 ns, tp(clear) =
tp(preset) = 30 ns, PRR = 1 MHz, and ZOUT ≈ 50Ω.
3. CL = 50 pF, minimum (CL includes probe and jig capacitance).
4. RL = 390Ω 5%.
5. All diodes are 1N3064, or equivalent.
6. When testing clear to output switching, preset input shall have a negative pulse. When
testing preset output switching, clear shall have a negative pulse (see table III).
FIGURE 4. Clear and preset switching test circuit and waveforms for device type 01.
23
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |