| TABLE III. Group A inspection for device type 08 - Continued
Terminal conditions (pins not designated may be high ≥ 2.0 V or low ≤ 0.7 V or open).
MIL-STD- Cases E,F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Measured Test Limits
Unit
terminal
Subgroup Symbol
883
Cases 2, X
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
method
Test no.
Shift
CLK
E
F
G
H
Serial
A
B
C
D
CLK
VCC
Min
Max
GND
QH
QH
Load
INP
INHB
1
IIL1
3009
27
GND
0.4 V
5.5 V
CLK/INHB
1/
1/
mA
Tc = 25C IIL7
28
0.4 V
"
"
1/
1/
mA
A
IIH1
3010
29
2.7 V
"
"
CLK
20
30
2.7 V
"
"
E
"
"
31
2.7 V
"
"
F
"
"
32
2.7 V
"
"
G
"
"
33
2.7 V
"
"
H
"
"
34
"
2.7 V
"
S/INP
"
"
35
"
2.7 V
"
A
"
"
36
"
2.7 V
"
B
"
"
37
"
2.7 V
"
C
"
"
38
"
2.7 V
"
D
"
"
39
"
2.7 V
"
CLK/INHB
"
"
"
IIH11
40
2.7 V
"
S/L
60
"
IIH2
41
5.5 V
"
"
CLK
0.1
mA
42
5.5 V
"
"
E
"
"
43
5.5 V
"
"
F
"
"
44
5.5 V
"
"
G
"
"
45
5.5 V
"
"
H
"
"
46
"
5.5 V
"
S/INP
"
"
47
"
5.5 V
"
A
"
"
48
"
5.5 V
"
B
"
"
49
"
5.5 V
"
C
"
"
50
"
5.5 V
"
D
"
"
51
"
5.5 V
"
CLK/INHB
"
"
"
52
5.5 V
"
S/L
0.3
"
IIH12
IOS
3011
53
GND
5.5 V
"
GND
"
QH
-15
-100
"
IOS
3011
54
"
GND
GND
"
"
"
-15
-100
QH
ICC
3005
55
"
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
"
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
4.5 V
"
VCC
36
"
ICC
3005
56
"
4.5 V
GND
GND
GND
GND
"
GND
GND
GND
GND
GND
4.5 V
"
VCC
36
"
Same tests, terminal conditions, and limits as subgroup 1, except TC = 125C and VIC tests are omitted.
2
Same tests, terminal conditions, and limits as subgroup 1, except TC = -55C and VIC tests are omitted.
3
See footnotes at end of device type 08.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |