| TABLE III. Group A inspection for device type 01.
Terminal conditions (pins not designated may be high ≥ 2.0 V, low ≤ 0.7 V, or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-
E, F
Subgroup Symbol STD-883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method -
2
terminal
Q2
Cext2
Rext2
GND
A2
B2
CLR2
Q1
Cext1
Rext1
VCC
Min
Max
Test no.
A1
B1
CLR1
Q1
Q2
2.5
V
1
VOH
3006
1
2.0 V
0.7 V
2.0 V
-.4 mA
GND
4.5 V
Q1
Tc = 25C
"
2
C
2.0 V
2.0 V
"
-.4 mA
GND
"
Q1
"
"
"
"
"
3
"
2.0 V
0.7 V
2.0 V
-.4 mA
"
Q2
"
4
-.4 mA
GND
"
C
2.0 V
2.0 V
"
Q2
"
"
VOL
3007
5
2.0 V
0.7 V
2.0 V
"
4 mA
"
Q1
0.4
"
"
"
"
6
C
2.0 V
2.0 V
4 mA
"
GND
"
Q1
"
7
4 mA
"
2.0 V
0.7 V
2.0 V
"
Q2
"
"
"
"
"
8
GND
"
C
2.0 V
2.0 V
4 mA
"
Q2
VI C
9
-18 mA
"
"
A1
-1.5
"
10
-18 mA
"
"
B1
"
"
11
-18 mA
"
"
CLR1
"
"
12
"
-18 mA
"
A2
"
"
13
"
-18 mA
"
B2
"
"
14
"
-18 mA
"
CLR2
"
"
A
IIL1
3009
15
0.4 V
"
5.5 V
A1
-160
-400
See
"
16
0.4 V
"
"
B1
"
"
"
note K
"
17
0.4 V
"
"
CLR1
"
"
"
"
18
"
0.4 V
"
A2
"
"
"
"
19
"
0.4 V
"
B2
"
"
"
"
20
"
0.4 V
"
CLR2
"
"
"
IIH1
3010
21
2.7 V
"
"
A1
20
"
"
22
2.7 V
"
"
B1
"
"
"
23
2.7 V
"
"
CLR1
"
"
"
24
"
2.7 V
"
A2
"
"
"
25
"
2.7 V
"
B2
"
"
"
26
"
2.7 V
"
CLR2
"
"
IIH2
"
27
5.5 V
"
"
A1
100
"
"
28
5.5 V
"
"
B1
"
"
"
29
5.5 V
"
"
CLR1
"
"
"
30
"
5.5 V
"
A2
"
"
"
31
"
5.5 V
"
B2
"
"
"
32
"
5.5 V
"
CLR2
"
"
-15
-100
mA
IOS
3011
33 CKT
GND
GND
GND
GND
"
"
Q1
A, D
-30
-130
"
"
33 CKT
GND
GND
GND
GND
"
"
Q1
C
"
34 CKT
C
4.5 V
4.5 V
"
GND
GND
"
Q1
-15
-100
"
A, D
"
34 CKT
C
4.5 V
4.5 V
"
GND
GND
"
Q1
-30
-130
"
C
-15
-100
"
"
35 CKT
"
GND
GND
GND
GND
"
Q2
A, D
-30
-130
"
"
35 CKT
"
GND
GND
GND
GND
"
Q2
C
"
36 CKT
GND
GND
"
C
4.5 V
4.5 V
"
Q2
-15
-100
"
A, D
"
36 CKT
GND
GND
"
C
4.5 V
4.5 V
"
Q2
-30
-130
"
C
See footnotes at end of this table.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |