TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated may be high 2.0 V; low 0.8 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
E, F
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2 1/
terminal
Test no.
S
QA
I0A
I1A
I1B
I0B
QB
GND
CP
QC
I0C
I1C
I1D
I0D
QD
VCC
Min
Max
1
IOS
3011
57
0.0 V
5.5 V
5.5 V
GND
2/
5.5 V
QA
-60
-150
mA
Tc = 25C
"
58
5.5 V
5.5 V
0.0 V
"
"
"
QB
"
"
"
"
59
"
"
0.0 V
5.5 V
5.5 V
"
QC
"
"
"
"
60
"
"
5.5 V
5.5 V
0.0 V
"
QD
"
"
"
IOD
61
2.5 V
0.0 V
0.0 V
"
"
4.5 V
QA
60
"
62
0.0 V
0.0 V
2.5 V
"
"
"
QB
"
"
63
"
"
2.5 V
0.0 V
0.0 V
"
QC
"
"
64
"
"
0.0 V
0.0 V
2.5 V
"
QD
"
"
ICC
3005
65
5.5 V
5.5 V
5.5 V
5.5 V
"
"
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
VCC
34
"
Same tests, terminal conditions, and limits as subgroup 1, except TC = +125C and VI C tests are omitted.
2
Same tests, terminal conditions, and limits as subgroup 1, except TC = -55C and VI C tests are omitted.
3
7
Func-
3014
66
B
B
A
A
B
GND
B
B
A
A
B
3/
Tc = 25C  tional
"
67
"
L
"
"
"
"
L
"
A
L
"
"
"
"
L
"
test
"
68
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
4/
"
69
"
"
A
B
"
"
"
"
B
"
"
"
"
"
"
"
"
70
"
H
"
"
"
"
"
"
A
"
"
"
"
"
"
"
"
71
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
72
"
"
B
A
B
A
"
"
B
"
"
"
"
"
"
"
"
73
"
L
"
"
"
"
H
"
A
"
"
"
"
"
"
"
"
74
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
75
"
"
"
"
A
B
"
"
B
"
A
B
"
"
"
"
"
76
"
"
"
"
"
"
L
"
A
H
"
"
"
"
"
"
"
77
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
78
"
"
"
"
"
"
"
"
B
"
B
A
B
A
"
"
"
79
"
"
"
"
"
"
"
"
A
L
"
"
"
"
H
"
"
80
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
81
"
"
"
"
"
"
"
"
B
"
"
"
A
B
"
"
"
82
"
"
"
"
"
"
"
"
A
"
"
"
"
"
L
"
"
83
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
84
A
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
85
"
H
"
"
"
"
H
"
A
H
"
"
"
"
H
"
"
86
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
87
"
"
A
B
B
A
"
"
B
"
A
B
B
A
"
"
"
88
"
L
A
B
B
A
L
"
A
L
A
B
B
A
L
"
"
89
"
"
B
A
A
B
"
"
A
"
B
A
A
B
"
"
"
90
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
91
"
H
"
"
"
"
H
"
A
H
"
"
"
"
H
"
"
92
"
"
A
B
B
A
H
"
A
"
A
B
B
A
"
"
"
93
"
"
"
"
"
"
H
"
B
"
"
"
"
"
"
"
"
94
"
L
"
"
"
"
L
"
A
L
"
"
"
"
L
"
"
95
B
"
"
"
"
"
"
"
A
"
"
"
"
"
"
"
"
96
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
97
"
H
"
"
"
"
H
"
A
H
"
"
"
"
H
"
"
98
"
"
B
A
A
B
"
"
A
"
B
A
A
B
"
"
"
99
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
100
"
L
"
"
"
"
L
"
A
L
"
"
"
"
L
"
"
101
"
L
"
"
"
"
L
"
B
L
"
"
"
"
L
"
Same tests, terminal conditions, and limits as for subgroup 7, except Tc = +125C and TC = -55C.
8
See footnotes at end of device type 02.