| 1/
Pins not references are N/C.
3.0 V 5.5 V
2/
Apply
0.0 V pulse prior to test.
3/
Method 3011 shall be used, except the output voltage shall be as specified herein, and the output
current shall be operating rather than short circuit current. The output conditions have been chosen
to produce a current that closely approximates one half of the true short circuit output current Ios.
4/
Tests shall be performed in sequence, attributes data only.
Output voltages shall be either: (1) H ≥ 2.4 V minimum and L ≤ 0.4 V maximum when using a high-speed
5/
checker double comparator; (2) H ≥ 1.5 V and L ≤ 1.5 V when using high-speed checker single comparator.
6/
fMAX limit is the frequency of the input pulse. The output frequency shall be one-half the input frequency.
7/
IIL limits shall be as follows:
Min/Max limits in (A) for circuit
Test
A
B
C
IIL3
0/-200
0/-200
0/-200
8/
A = 3.0 V minimum; B = 0.0 V or GND.
|