| TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated may be high 2.0 V; low 0.8 V; or open).
MIL-STD- Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Subgroup Symbol
883
R, S, 2
Measured
Test limits
Unit
method Test no.
1D
2D
3D
4D
5D
6D
7D
8D
GND
ENC
VCC
terminal
Min
Max
8Q
7Q
6Q
5Q
4Q
3Q
2Q
1Q
OC
7 4/
Truth
3014
84
B
A
A
A
A
A
A
A
A
GND
A
L
L
L
L
L
L
L
L
5.0 V
All
5/
5/
Tc = 25 table
85
"
B
B
B
B
B
B
B
B
"
"
H
H
H
H
H
H
H
H
"
outputs
C
test
86
"
A
A
A
A
A
A
A
A
"
"
L
L
L
L
L
L
L
L
"
"
87
"
A
A
A
A
A
A
A
A
"
B
"
"
"
"
"
"
"
"
"
"
88
"
B
B
B
B
B
B
B
B
"
B
"
"
"
"
"
"
"
"
"
"
89
"
"
"
"
"
"
"
"
"
"
A
H
H
H
H
H
H
H
H
"
"
90
"
"
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
"
"
"
91
"
A
A
A
A
A
A
A
A
"
B
"
"
"
"
"
"
"
"
"
"
92
"
A
A
A
A
A
A
A
A
"
A
L
L
L
L
L
L
L
L
"
"
Same tests, terminal conditions, and limits as for subgroup 7, except Tc = +125 and TC = -55 .
8
C
C
9
tPLH2
3003
93
GND
GND
GND
IN
OUT
5.0 V
8
22
ns
ENC to 1 Q
Tc = 25
Fig. 4
94
"
GND
"
"
OUT
"
"
"
"
C
ENC to 2 Q
"
95
"
GND
"
"
OUT
"
"
"
"
ENC to 3 Q
"
96
"
GND
"
"
OUT
"
"
"
"
ENC to 4 Q
"
97
"
GND
"
"
OUT
"
"
"
"
ENC to 5 Q
"
98
"
GND
"
"
OUT
"
"
"
"
ENC to 6 Q
"
99
"
GND
"
"
OUT
"
"
"
"
ENC to 7 Q
"
100
"
GND
"
"
OUT
"
"
"
"
ENC to 8 Q
tPHL2
"
101
"
4.5 V
"
"
OUT
"
8
21
"
ENC to 1 Q
"
102
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 2 Q
"
103
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 3 Q
"
104
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 4 Q
"
105
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 5 Q
"
106
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 6 Q
"
107
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 7 Q
"
108
"
4.5 V
"
"
OUT
"
"
"
"
ENC to 8 Q
tPLH3
"
109
"
IN
"
"
OUT
"
3
18
"
1D to 1 Q
"
110
"
IN
"
"
OUT
"
"
"
"
2D to 2 Q
"
111
"
IN
"
"
OUT
"
"
"
"
3D to 3 Q
"
112
"
IN
"
"
OUT
"
"
"
"
4D to 4 Q
"
113
"
IN
"
"
OUT
"
"
"
"
5D to 5 Q
"
114
"
IN
"
"
OUT
"
"
"
"
6D to 6 Q
"
115
"
IN
"
"
OUT
"
"
"
"
7D to 7 Q
"
116
"
IN
"
"
OUT
"
"
"
"
8D to 8 Q
See footnotes at end of device type 02.
|