| TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated are open)
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-
A, B, D
STD-883
Case C
11
12
1
14
13
2
3
4
5
6
7
8
9
10
Test limits
Unit
Subgroup
Symbol
method
Measured
Min
Max
Test no.
X
1B
2A
2B
2C
2D
2Y
GND
1Y
1C
1D
1A
x
VCC
terminal
A
3010
31
5.5 V
5.5 V
GND
GND
1A
100
1
IIH2
"
32
GND
"
5.5 V
"
1B
"
"
TC = +25C
"
33
"
"
5.5 V
GND
1C
"
"
"
34
"
"
GND
5.5 V
1D
"
"
"
35
"
5.5 V
GND
"
2A
"
"
"
36
"
GND
5.5 V
"
2B
"
"
"
37
"
5.5 V
GND
"
2C
"
"
"
38
"
GND
5.5 V
"
2D
"
"
3011
39
GND
"
GND
"
GND
GND
GND
1Y
-40
-100
mA
IOS
3011
40
"
GND
GND
GND
GND
GND
"
2Y
-40
-100
"
3005
41
5.5 V
"
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
5.5 V
24
"
VCC
ICCL
"
3005
42
GND
"
GND
GND
GND
GND
GND
"
GND
GND
13
VCC
ICCH
43
-12 mA
4.5 V
"
1A
-1.5
V
VIC
44
"
-12 mA
"
1B
"
"
45
"
"
-12 mA
1C
"
"
46
"
"
-12 mA
1D
"
"
47
"
-12 mA
"
2A
"
"
48
"
-12 mA
"
2B
"
"
49
"
-12 mA
"
2C
"
"
50
"
-12 mA
"
2D
"
"
3/
51
1.4 V
GND
"
GND
GND
GND
GND
GND
"
GND
GND
-5.85
mA
IX
x
4/
52
0.7 mA
GND
"
GND
GND
GND
GND
GND
"
20 mA
GND
GND
X
1.1
V
VBE
2
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125C and VIC tests are omitted.
3
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55C and VIC tests are omitted.
See notes at end of device type 01.
|