| TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated are open)
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-
A, B, D
STD-883
Case C
11
12
1
14
13
2
3
4
5
6
7
8
9
10
Test limits
Unit
Subgroup
Symbol
method
Measured
Min
Max
Test no.
X
1B
2A
2B
2C
2D
2Y
GND
1Y
1C
1D
1A
x
VCC
terminal
3003
53
IN
5.0 V
2.4 V
GND
OUT
GND
GND
1A to 1Y
2
13
ns
9
tPHL1
Fig. 4
54
"
IN
2.4 V
GND
GND
OUT
"
2A to 2Y
"
13
"
TC = +25C
"
55
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
15
"
tPHL2
"
56
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
14
"
tPLH1
"
57
"
IN
2.4 V
GND
GND
OUT
"
2A to 2Y
"
14
"
"
58
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
18
"
tPLH2
"
59
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
"
"
10
tPHL1
"
60
"
IN
2.4 V
GND
GND
OUT
"
2A to 2Y
"
"
"
TC = +125C
"
61
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
22
"
tPHL2
"
62
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
18
"
tPLH1
"
63
"
IN
2.4 V
GND
GND
OUT
"
2A to 2Y
"
18
"
"
64
IN
"
2.4 V
"
OUT
GND
GND
1A to 1Y
"
26
"
tPLH2
11
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55C.
1/ At the manufacturer's option, the high and low level output voltage tests for the expanded inputs may be verified by performing
either tests 5 and 12 or 5a and 12a.
2/ R1 = 68 ohms between X and X .
3/ See figure 5.
4/ See figure 6.
|