TABLE III. Group A inspection for device type 01 - Continued.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1A
1Y
2Y
2A
VEE
4Y
3A
3Y
B
4A
VCC2
Min
Max
1Y
2Y
3Y
4Y
9
tTHL
3004
84
E3
LD2
LD2
IN
OUT
LD2
E2
LD2
LD2
LD2
LD2
E3
1Y
1.1
3.3
ns
Tc = 25C
"
85
"
OUT
"
IN
LD2
"
"
"
"
"
"
"
"
"
"
1Y
"
86
"
LD2
"
"
OUT
IN
"
"
"
"
"
"
2Y
"
"
"
"
"
"
"
87
"
"
OUT
"
LD2
IN
"
"
"
"
"
"
2Y
"
88
"
"
LD2
"
"
"
"
IN
OUT
"
"
"
3Y
"
"
"
"
89
"
"
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
"
3Y
"
90
"
"
"
"
"
"
OUT
"
IN
LD2
"
"
4Y
"
"
"
"
"
"
"
91
"
"
"
"
"
"
LD2
"
IN
"
OUT
"
4Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
4.0
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
4.0
ns
9
tPLH
3003
92
E3
LD2
LD2
IN
OUT
LD2
E2
LD2
LD2
LD2
LD2
E3
1Y
1.0
2.9
ns
Tc = 25C
"
"
"
"
"
"
"
"
"
"
"
93
"
OUT
"
IN
LD2
1Y
"
94
"
LD2
"
"
OUT
IN
"
"
"
"
"
"
2Y
"
"
"
"
95
"
"
OUT
"
LD2
IN
"
"
"
"
"
"
"
"
"
2Y
"
96
"
"
LD2
"
"
"
"
IN
OUT
"
"
"
3Y
"
"
"
"
97
"
"
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
"
3Y
"
98
"
"
"
"
"
"
OUT
"
IN
LD2
"
"
4Y
"
"
"
"
99
"
"
"
"
"
"
LD2
"
IN
"
OUT
"
"
"
"
4Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
3.7
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
3.7
ns
9
tPHL
3003
100
E3
LD2
LD2
IN
OUT
LD2
E2
LD2
LD2
LD2
LD2
E3
1Y
1.0
2.9
ns
Tc = 25C
"
101
"
OUT
"
IN
LD2
"
"
"
"
"
"
"
"
"
"
1Y
"
102
"
LD2
"
"
OUT
IN
"
"
"
"
"
"
2Y
"
"
"
"
103
"
"
OUT
"
LD2
IN
"
"
"
"
"
"
"
"
"
2Y
"
104
"
"
LD2
"
"
"
"
IN
OUT
"
"
"
3Y
"
"
"
"
105
"
"
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
"
3Y
"
106
"
"
"
"
"
"
OUT
"
IN
LD2
"
"
4Y
"
"
"
"
107
"
"
"
"
"
"
LD2
"
IN
"
OUT
"
"
"
"
4Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
3.7
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
3.7
ns