|
| TABLE III. Group A inspection for device type 02.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1A
1B
2A
2B
VEE
4Y
3A
3B
4A
4B
VCC2
Min
Max
1Y
2Y
3Y
4Y
1
VOH
3006
1
GND
LD1
LD1
VIL1
E1
LD1
LD1
LD1
GND
0.930
-0.780
V
1Y
Tc = 25C
"
2
"
"
"
VIL1
"
"
"
"
"
"
"
"
"
2Y
"
3
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
3Y
"
4
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
4Y
"
5
"
"
"
"
"
"
VIH1
"
"
"
4Y
"
"
"
"
"
"
"
6
"
"
"
VIL1
"
"
"
"
"
"
1Y
"
7
"
"
"
VIL1
"
"
"
"
"
"
"
"
2Y
"
8
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
3Y
"
9
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
4Y
"
10
"
"
"
"
"
"
VIH1
"
"
"
4Y
"
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-0.825
-0.630
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.080
-0.880
V
1
VOL
3007
11
GND
LD1
LD1
E1
LD1
VIL1
LD1
LD1
GND
4Y
-.1.850
-1.620
V
Tc = 25C
"
"
"
"
12
"
"
"
VIH1
"
"
"
"
"
1Y
"
13
"
"
"
VIH1
"
"
"
"
"
"
"
"
"
2Y
"
14
"
"
"
"
"
"
VIH1
"
"
"
"
"
"
3Y
"
15
"
"
"
"
"
"
VIH1
"
"
"
"
"
"
4Y
"
16
"
"
"
"
"
"
VIL1
"
"
"
4Y
"
"
"
"
17
"
"
"
VIH1
"
"
"
"
"
"
"
"
"
1Y
"
18
"
"
"
VIH1
"
"
"
"
"
"
"
"
2Y
"
19
"
"
"
"
"
VIH1
"
"
"
"
"
"
3Y
"
20
"
"
"
"
"
VIH1
"
"
"
"
"
"
4Y
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.820
-1.545
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.920
-1.655
V
VOTH
21
GND
LD1
LD1
VITL
E1
LD1
LD1
LD1
GND
-0.950
V
1Y
22
"
"
"
VITL
"
"
"
"
"
"
"
"
2Y
23
"
"
"
"
"
"
VITL
"
"
"
"
"
3Y
24
"
"
"
"
"
"
VITL
"
"
"
"
"
4Y
25
"
"
"
"
"
"
VITH
"
"
"
4Y
"
"
26
"
"
"
VITL
"
"
"
"
"
"
"
"
1Y
27
"
"
"
VITL
"
"
"
"
"
"
"
2Y
28
"
"
"
"
"
"
VITL
"
"
"
"
"
3Y
29
"
"
"
"
"
"
VITL
"
"
"
"
"
4Y
30
"
"
"
"
"
"
VITH
"
"
"
4Y
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-0.845
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.100
V
VOTL
31
GND
LD1
LD1
E1
LD1
VITL
LD1
LD1
GND
4Y
-1.600
V
32
"
"
"
VITH
"
"
"
"
"
"
"
1Y
33
"
"
"
VITH
"
"
"
"
"
"
"
"
2Y
34
"
"
"
"
"
"
VITH
"
"
"
"
"
3Y
35
"
"
"
"
"
"
VITH
"
"
"
"
"
4Y
36
"
"
"
"
"
"
VITL
"
"
"
4Y
"
"
"
"
37
"
"
"
VITH
"
"
"
"
"
"
1Y
"
"
38
"
"
"
VITH
"
"
"
"
"
2Y
39
"
"
"
"
"
VITH
"
"
"
"
"
3Y
40
"
"
"
"
"
VITH
"
"
"
"
"
4Y
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.525
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.635
V
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |