| TABLE III. Group A inspection for device type 05 - Continued.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1Y
1A
1B
2B
VEE
2A
2Y
3Y
3A
3B
VCC2
Min
Max
1Y
2Y
3Y
9
tPHL
3003
113
E3
LD2
OUT
IN
VIH2
E2
LD2
LD2
LD2
LD2
E3
1Y
1.1
3.7
ns
Tc = 25C
"
114
"
"
"
IN
VIL2
"
"
"
"
"
"
1Y
"
"
"
"
115
"
"
"
VIL2
IN
"
"
"
"
"
"
1Y
"
"
"
"
116
"
"
"
VIH2
"
"
"
"
"
"
"
1Y
"
"
"
"
"
"
"
117
"
OUT
LD2
VIL2
"
"
"
"
"
"
"
1Y
"
"
"
"
118
"
"
"
VIH2
"
"
"
"
"
"
"
1Y
"
119
"
"
"
IN
VIH2
"
"
"
"
"
"
"
"
"
1Y
"
"
"
"
120
"
"
"
IN
VIL2
"
"
"
"
"
"
1Y
"
121
"
LD2
"
IN
"
VIH2
OUT
"
"
"
"
2Y
"
"
"
"
122
"
"
"
IN
"
VIL2
"
"
"
"
"
2Y
"
"
"
"
123
"
"
"
VIL2
"
IN
"
"
"
"
"
2Y
"
"
"
"
124
"
"
"
VIH2
"
"
"
"
"
"
"
2Y
"
"
"
"
125
"
"
"
VIL2
"
"
LD2
OUT
"
"
"
"
"
"
2Y
"
126
"
"
"
VIH2
"
"
"
"
"
"
"
"
"
"
2Y
"
"
"
"
127
"
"
"
IN
"
VIH2
"
"
"
"
"
2Y
"
128
"
"
"
IN
"
VIL2
"
"
"
"
"
"
"
"
2Y
"
129
"
"
"
"
"
LD2
"
OUT
IN
VIL2
"
3Y
"
"
"
"
130
"
"
"
"
"
"
"
"
IN
VIH2
"
3Y
"
"
"
"
131
"
"
"
"
"
"
"
"
VIL2
IN
"
3Y
"
"
"
"
132
"
"
"
"
"
"
"
"
VIH2
"
"
3Y
"
"
"
"
"
"
"
133
"
"
"
"
"
"
OUT
LD2
VIL2
"
"
3Y
"
134
"
"
"
"
"
"
"
"
VIH2
"
"
"
"
"
3Y
"
135
"
"
"
"
"
"
"
"
IN
VIH2
"
"
"
"
3Y
"
136
"
"
"
"
"
"
"
"
IN
VIL2
"
"
"
"
3Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
4.5
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
4.5
ns
|