| TABLE III. Group A inspection for device type 06.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1Y
1A
1B
1C
1D
VEE
2A
2B
2C
2D
2E
2Y
VCC2
Min
Max
1Y
2Y
1
VOH
3006
1
GND
LD1
LD1
VIH1
E1
LD1
LD1
GND
1Y
-0.930
-0.780
V
Tc = 25C
"
2
"
"
"
VIH1
"
"
"
"
1Y
"
"
"
"
3
"
"
"
VIH1
"
"
"
"
1Y
"
"
"
"
4
"
"
"
VIH1
"
"
"
"
1Y
"
"
"
"
5
"
"
"
"
VIH1
"
"
"
2Y
"
"
"
"
6
"
"
"
"
VIH1
"
"
"
2Y
"
"
"
"
7
"
"
"
"
VIH1
"
"
"
2Y
"
"
"
"
8
"
"
"
"
VIH1
"
"
"
2Y
"
"
"
"
9
"
"
"
"
VIH1
"
"
"
2Y
"
"
"
"
"
"
"
10
"
"
"
VIL1
"
"
"
"
1Y
"
11
"
"
"
VIL1
"
"
"
"
"
"
"
1Y
"
12
"
"
"
VIL1
"
"
"
"
"
"
"
1Y
"
"
"
"
13
"
"
"
VIL1
"
"
"
"
1Y
"
"
"
"
14
"
"
"
"
VIL1
"
"
"
2Y
"
15
"
"
"
"
VIL1
"
"
"
"
"
"
2Y
"
16
"
"
"
"
VIL1
"
"
"
"
"
"
2Y
"
17
"
"
"
"
VIL1
"
"
"
"
"
"
2Y
"
"
"
"
18
"
"
"
"
VIL1
"
"
"
2Y
Same tests and terminal conditions as for subgroup 1, except Tc = -125C and limits as shown.
2
-0.825
-0.630
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.080
-0.880
V
1
VOL
3007
19
GND
LD1
LD1
VIL1
"
LD1
LD1
GND
1Y
-1.850
-1.620
V
Tc = 25C
"
20
"
"
"
VIL1
"
"
"
"
1Y
"
"
"
"
21
"
"
"
VIL1
"
"
"
"
1Y
"
"
"
"
22
"
"
"
VIL1
"
"
"
"
1Y
"
"
"
"
23
"
"
"
"
VIL1
"
"
"
2Y
"
"
"
"
24
"
"
"
"
VIL1
"
"
"
2Y
"
"
"
"
25
"
"
"
"
VIL1
"
"
"
2Y
"
"
"
"
26
"
"
"
"
VIL1
"
"
"
2Y
"
"
"
"
27
"
"
"
"
VIL1
"
"
"
2Y
"
"
"
"
28
"
"
"
VIH1
E1
"
"
"
"
"
"
1Y
"
29
"
"
"
VIH1
"
"
"
"
"
"
"
1Y
"
30
"
"
"
VIH1
"
"
"
"
"
"
"
1Y
"
31
"
"
"
VIH1
"
"
"
"
"
"
"
1Y
"
32
"
"
"
"
VIH1
"
"
"
"
"
"
2Y
"
33
"
"
"
"
VIH1
"
"
"
"
"
"
2Y
"
34
"
"
"
"
VIH1
"
"
"
"
"
"
2Y
"
35
"
"
"
"
VIH1
"
"
"
"
"
"
2Y
"
36
"
"
"
"
VIH1
"
"
"
"
"
"
2Y
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.820
-1.545
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.920
-1.655
V
1
VOTH
37
GND
LD1
LD1
VITH
E1
LD1
LD1
GND
1Y
-0.950
V
38
"
"
"
VITH
"
"
"
"
1Y
"
"
39
"
"
"
VITH
"
"
"
"
1Y
"
"
40
"
"
"
VITH
"
"
"
"
1Y
"
"
41
"
"
"
"
VITH
"
"
"
2Y
"
"
42
"
"
"
"
VITH
"
"
"
2Y
"
"
43
"
"
"
"
VITH
"
"
"
2Y
"
"
44
"
"
"
"
VITH
"
"
"
2Y
"
"
45
"
"
"
"
VITH
"
"
"
2Y
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-0.845
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.100
V
|