| TABLE III. Group A inspection for device type 05. Continued.
MIL-
Cases
Terminal conditions
1/
Test limits
Symbol
STD-
2
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Subgroup 1
Subgroup 2
Subgroup 3
Measured
Unit
TC = +25C
TC = +125C
TC = -55C
883
Terminal
C and D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
method
Test no.
1A
1B
1Y
2A
2B
2Y
GND
3Y
3A
3B
4Y
4A
4B
VCC
Min
Max
Min
Max
Min
Max
A
47
4.2 V
4.2 V
5.2mA
GND
6V
1Y
0.26
0.4
0.26
VOL5
3007
48
4.2 V
4.2 V
5.2mA
"
"
2Y
"
"
"
"
49
"
5.2mA
4.2 V
4.2 V
"
3Y
"
"
"
"
50
"
5.2mA
4.2 V
4.2 V
"
4Y
"
"
"
"
51
5/
6V
GND
6V
1Y
2.1
4.2
2.1
4.2
2.1
4.2
V
VT+
3006
52
6V
5/
"
"
1Y
"
"
"
"
"
"
53
5/
6V
"
"
2Y
"
"
"
"
"
"
54
6V
5/
"
"
2Y
"
"
"
"
"
"
55
"
5/
6V
"
3Y
"
"
"
"
"
"
56
"
6V
5/
"
3Y
"
"
"
"
"
"
57
"
5/
6V
"
4Y
"
"
"
"
"
"
5/
"
4Y
"
"
"
"
"
"
58
"
6V
59
6/
GND
"
1Y
0.6
2.5
0.6
2.5
0.6
2.5
"
VH
60
6/
"
"
1Y
"
"
"
"
"
"
"
61
6/
"
"
2Y
"
"
"
"
"
"
"
62
6/
"
"
2Y
"
"
"
"
"
"
"
63
"
6/
"
3Y
"
"
"
"
"
"
"
64
"
6/
"
3Y
"
"
"
"
"
"
"
65
"
6/
"
4Y
"
"
"
"
"
"
"
66
"
6/
"
4Y
"
"
"
"
"
"
"
67
GND
GND
GND
"
4V
1Y
-10
-120
-10
-120
-10
-120
mA
IOS4
3011
68
GND
GND
GND
"
"
2Y
"
"
"
"
"
"
"
69
"
GND
GND
GND
"
3Y
"
"
"
"
"
"
"
70
"
GND
GND
GND
"
4Y
"
"
"
"
"
"
"
A
71
6V
GND
GND
6V
1A
0.05
0.1
IIH
3010
72
GND
6V
"
"
1B
"
"
"
73
6V
GND
"
"
2A
"
"
"
74
GND
6V
"
"
2B
"
"
"
75
"
6V
GND
"
3A
"
"
"
76
"
GND
6V
"
3B
"
"
"
77
"
6V
GND
"
4A
"
"
"
78
"
GND
6V
"
4B
"
"
"
79
GND
6V
GND
"
1A
-0.05
-0.1
"
IIL
3009
80
6V
GND
"
"
1B
"
"
"
81
GND
6V
"
"
2A
"
"
"
82
6V
GND
"
"
2B
"
"
"
83
"
GND
6V
"
3A
"
"
"
84
"
6V
GND
"
3B
"
"
"
85
"
GND
6V
"
4A
"
"
"
86
"
6V
GND
"
4B
"
"
"
Subgroup 4
TC= +25C
Min
Max
87
2/
1/
GND
1A
10
pF
CIN
3012
88
2/
"
"
1B
"
"
89
2/
"
"
2A
"
"
90
2/
"
"
2B
"
"
91
"
2/
"
3A
"
"
92
"
2/
"
3B
"
"
93
"
2/
"
4A
"
"
94
"
2/
"
4B
"
"
See footnotes at end of table.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |