| TABLE III. Group A inspection for device type 05. Continued.
Cases
Terminal conditions 1/
Test limits
Measured
Unit
Symbol
MIL-
2
2
3
4
6
8
9
10
12
13
14
16
18
19
20
3/
3/
Terminal
STD-
Subgroup 9
Subgroup 11
Subgroup 10
C and D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
883
TC = +25C
TC = +125C
TC = -55C
method
Test no.
1A
1B
1Y
2A
2B
2Y
GND
3Y
3A
3B
4Y
4A
4B
VCC
Min
Max
Min
Max
Min
Max
tPHL
3003
95
IN
4.5 V
OUT
GND
4.5 V
1A to 1Y
4
23
4
29
4
23
ns
(fig. 3)
96
4.5 V
IN
OUT
"
"
1B to 1Y
"
"
"
"
"
"
"
97
IN
4.5 V
OUT
"
"
2A to 2Y
"
"
"
"
"
"
"
98
4.5 V
IN
OUT
"
"
2B to 2Y
"
"
"
"
"
"
"
99
"
OUT
IN
4.5 V
"
3A to 3Y
"
"
"
"
"
"
"
100
"
OUT
4.5
IN
"
3B to 3Y
"
"
"
"
"
"
"
101
"
OUT
IN
4.5 V
"
4A to 4Y
"
"
"
"
"
"
"
102
"
OUT
4.5 V
IN
"
4B to 4Y
"
"
"
"
"
"
"
tPLH
3003
103
IN
4.5 V
OUT
"
"
1A to 1Y
4
23
4
29
4
23
"
(fig. 3)
104
4.5 V
IN
OUT
"
"
1B to 1Y
"
"
"
"
"
"
"
105
IN
4.5 V
OUT
"
"
2A to 2Y
"
"
"
"
"
"
"
106
4.5 V
IN
OUT
"
"
2B to 2Y
"
"
"
"
"
"
"
107
"
OUT
IN
4.5 V
"
3A to 3Y
"
"
"
"
"
"
"
108
"
OUT
4.5 V
IN
"
3B to 3Y
"
"
"
"
"
"
"
109
"
OUT
IN
4.5 V
"
4A to 4Y
"
"
"
"
"
"
"
110
"
OUT
4.5 V
IN
"
4B to 4Y
"
"
"
"
"
"
"
tTHL
3004
111
IN
4.5 V
OUT
"
"
1Y
3
15
3
20
3
15
"
(fig. 3)
112
4.5 V
IN
OUT
"
"
1Y
"
"
"
"
"
"
"
113
IN
4.5 V
OUT
"
"
2Y
"
"
"
"
"
"
"
114
4.5 V
IN
OUT
"
"
2Y
"
"
"
"
"
"
"
115
"
OUT
IN
4.5 V
"
3Y
"
"
"
"
"
"
"
116
"
OUT
4.5 V
IN
"
3Y
"
"
"
"
"
"
"
117
"
OUT
IN
4.5 V
"
4Y
"
"
"
"
"
"
"
118
"
OUT
4.5 V
IN
"
4Y
"
"
"
"
"
"
"
tTLH
3004
119
IN
4.5 V
OUT
"
"
1Y
3
15
3
20
3
15
"
(fig. 3)
120
4.5 V
IN
OUT
"
"
1Y
"
"
"
"
"
"
"
121
IN
4.5 V
OUT
"
"
2Y
"
"
"
"
"
"
"
122
4.5 V
IN
OUT
"
"
2Y
"
"
"
"
"
"
"
123
"
OUT
IN
4.5 V
"
3Y
"
"
"
"
"
"
"
124
"
OUT
4.5 V
IN
"
3Y
"
"
"
"
"
"
"
125
"
OUT
IN
4.5 V
"
4Y
"
"
"
"
"
"
"
126
"
OUT
4.5 V
IN
"
4Y
"
"
"
"
"
"
"
See footnotes on next page.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |