| MIL-M-38510/653B
TABLE I. Electrical performance characteristics Continued.
Test
Symbol
Conditions 1/
Device
VCC
Limits
Unit
TC = +125C
type
Min Max
unless otherwise specified
mA
Short circuit output
IOS1 2/
VO = GND
01-05
2.0 V
-2
-50
VI = GND
current
07,08
06
-60
IOS2 2/
01-05 4.5 V
-15
-150
07,08,52
06
-165
IOS3 2/
01-05
6.0 V
-25
-180
07,08
06
-210
IOS4
01-05 4.0 V
-10
-120
07,08,52
06
-135
52
5.5 V
-25
-180
IOS5 2/
52
5.5 V
3.0
mA
Additional supply
For all inputs, VIL = 0.4 V and
ICCĆ 3/
current quiescent
VIH = 2.4 V
per input pin (one
Test pin at VIN = 2.4 V
unit load)
When not being tested, control
pins at VIH = VCC and VIL = GND
IO = 0 A
A
Quiescent supply
ICC
VIN = 6.0 V
01-05
6.0 V
15
current
52
06-08
20
A
VIN = 6.0 V
06
6.0 V
10
ICCZ
A
06
6.0 V
-2.0
Three-state output
IOZL
VOUT = GND
OC = VIH 4/
leakage current
low
A
Three-state output
IOZH
VOUT = VCC
06
6.0 V
+2.0
leakage current
OC = VIH 4/
high
TC = +25C
Control input
CC
All
15
pF
capacitance
Input capacitance
CI
All
10
Three-state output
CO
06
6.0 V
20
capacitance
pF
Power dissipation
CPD
01
30
capacitance
2/ 5/
02-05
35
06
29
07
38
08
65
52
30
CL = 50 pF 10%
Maximum clock
fMAX
01,03
23
4.5 V
MHz
6/ 7/
frequency
04,06
07
02,05
21
52
08
26
See footnotes at end of table.
7
|