MIL-M-38510/70C
TABLE I. Electrical performance characteristics - Continued.
Conditions
Limits
Device
Units
Test
Symbol
-55C TC +125C
Min
Max
type
unless otherwise specified
Output high
10
13
mA
Supply current
VCC = 5.5 V
ICC
Output low
10
16
mA
Output off
10
25
mA
01, 03,
2
9
ns
Propagation delay time,
CL = 50 pF; RL = 280;
tPHL
05, 06
high-to-low level
VCC = 5.0 V
02, 04, 07
2
14
ns
08
2
10
ns
09
2
12
ns
10
2
10.5
ns
01, 03,
2
9
ns
Propagation delay time,
CL = 50 pF; RL = 280;
tPLH
05, 06
low-to-high level
VCC = 5.0 V
02, 04, 07
2
14
ns
08, 09, 10
2
9
ns
10
2
25
ns
Output enable time to
CL = 50 pF; RL = 280;
tZH
high level
VCC = 5.0 V
10
2
26
ns
Output enable time to
CL = 50 pF; RL = 280;
tZL
low level
VCC = 5.0 V
10
2
11
ns
Output disable time from
CL = 15 pF; VCC = 5.0 V
tHZ
high level
10
2
17
ns
Output disable time from
CL = 15 pF; VCC = 5.0 V
tLZ
low level
1/ Not more than one output should be shorted at a time.