| MIL-M-38510/70C
TABLE II. Electrical test requirements.
Subgroups (see table III)
Class S
Class B
MIL-PRF-38535
Devices
Devices
Test requirement
Interim electrical parameters
1
1
Final electrical test
1*, 2, 3,
1*, 2, 3, 9
9, 10, 11
Group A test requirements
1, 2, 3,
1, 2, 3,
9, 10, 11
9, 10, 11
1, 2, 3,
Group B electrical test parameters
N/A
9, 10, 11
when using the method 5005 QCI option
1, 2, 3, 9,
Groups C end point electrical parameters
1, 2, 3
10, 11
Group D end point electrical parameters
1, 2, 3
1, 2, 3
* PDA applies to subgroup 1.
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups
specified in table II. The electrical tests for each subgroup are described in table III.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group
number 8 (see MIL-PRF-38535, appendix A).
4. PRODUCT ASSURANCE PROVISIONS VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535
or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall
not effect the form, fit, or function as described herein.
4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |