| TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open).
Cases X,
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
2 1/
MIL-
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup Symbol STD-883 E, F
Measured
Unit
method Test no. CLR
Min
Max
terminal
Q1
D1
D2
Q2
D3
Q3
GND
CLK
Q4
D4
Q5
D5
D6
Q6
VCC
Fig. 15
89
2.7 V
OUT
IN (D)
GND
IN (C)
5.0 V
CLK to Q1
2.0
19.0
ns
9
tPHL1
"
90
"
IN (D)
OUT
"
"
"
CLK to Q2
"
"
"
TC = +25C
"
91
"
IN (D)
OUT
"
"
"
CLK to Q3
"
"
"
"
92
"
"
"
OUT
IN (D)
"
CLK to Q4
"
"
"
"
93
"
"
"
OUT
IN (D)
"
CLK to Q5
"
"
"
"
94
"
"
"
IN (D)
OUT
"
CLK to Q6
"
"
"
Fig. 13
95
IN (F)
OUT
2.7 V
"
IN (G)
"
CLR to Q1
"
24.0
"
tPHL2
"
96
"
2.7 V
OUT
"
"
"
CLR to Q2
"
"
"
"
97
"
2.7 V
OUT
"
"
"
CLR to Q3
"
"
"
"
98
"
"
"
OUT
2.7 V
"
CLR to Q4
"
"
"
"
99
"
"
"
OUT
2.7 V
"
CLR to Q5
"
"
"
"
100
"
"
"
2.7 V
OUT
"
CLR to Q6
"
"
"
10
101-106
55
MHz
fMAX
7/
TC= +125C
107-112
2.0
17.0
ns
tPLH1
113-118
"
17.0
"
tPLH2
Same tests and terminal conditions as for subgroup 9, except TC = +125C and limits are as shown.
119-124
"
23.0
"
tPHL1
125-130
"
29.0
"
tPHL2
11
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55C.
1/ Cases X and 2 terminals not designated are NC.
2/ C = Normal clock pulse.
D = Momentary connection: 5.0 V to momentary GND to 5.0 V, occurs before measurement is made.
3/ At the manufacturers' option, IOS tests 45 through 50, the following alternate procedure may be used: Apply 2.75 V at test 45 Q1, test 46 Q2,
test 47 Q3, test 48 Q4, test 49 Q5, and test 50 Q6, using min/max limits of -20/-50 mA.
4/ Only a summary of attributes data is required.
5/ Inputs: A = 2.4 V minimum, B = 0.4 V.
6/ Outputs: H ≥ 1.5 V, L ≤ 1.5 V.
7/ fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
|