| TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
MIL-
A, B, C, D
Meas.
Subgroup
Symbol
STD-883
Min
Max
Unit
terminal
method
GND
CLK
CLR
Test No.
SIB
QA
QB
QC
QD
QE
QF
QG
QH
VCC
SIA
(Fig 6)
164
IN
IN
GND
IN
4.5 V
OUT
5.0 V
11
MHz
9
QH
fMAX
3003
165
OUT
"
GND
IN
"
12
49
ns
TC = 25C
tPHL1
QA
"
"
"
"
"
(Fig 6)
166
OUT
"
"
"
"
QB
"
"
"
"
"
"
167
OUT
"
"
"
"
QC
"
"
"
"
"
"
168
OUT
"
"
"
"
QD
"
"
"
"
"
"
169
"
"
"
OUT
"
QE
"
"
"
"
"
"
170
"
"
"
OUT
"
QF
"
"
"
'`
"
"
171
"
"
"
OUT
"
QG
"
"
"
'`
"
"
172
"
"
"
OUT
"
QH
"
173
IN
IN
OUT
"
IN
4.5 V
"
10
30
"
"
QA
tPLH2
"
"
"
"
"
"
174
"
"
OUT
"
"
"
"
QB
"
"
"
"
"
"
175
"
"
OUT
"
"
"
"
QC
"
"
"
"
"
"
176
"
"
OUT
"
"
"
"
QD
"
"
"
"
"
"
177
"
"
"
"
"
OUT
"
QE
"
"
"
"
"
"
178
"
"
"
"
"
OUT
"
QF
"
"
"
'`
"
"
179
"
"
"
"
"
OUT
"
QG
'`
"
"
"
"
"
180
"
"
"
"
"
OUT
"
QH
"
181
"
"
OUT
"
"
"
"
"
37
"
"
QA
tPHL2
"
"
"
"
"
"
182
"
"
OUT
"
"
"
"
QB
"
"
"
"
"
"
183
"
"
OUT
"
"
"
"
QC
"
"
"
"
"
"
184
"
"
OUT
"
"
"
"
QD
"
"
"
"
"
"
185
"
"
"
"
"
OUT
"
QE
"
"
"
"
"
"
186
"
"
"
"
"
OUT
"
QF
"
"
"
'`
"
"
187
"
"
"
"
"
OUT
"
QG
"
"
"
'`
"
"
188
"
"
"
"
"
OUT
"
QH
(Fig 6)
189
IN
IN
"
"
"
OUT
"
9
MHz
10
QH
fMAX
3003
190
OUT
"
GND
IN
"
12
63
ns
TC = 125C
tPHL1
QA
"
"
"
"
"
(Fig 6)
191
OUT
"
"
"
"
QB
"
"
"
"
"
"
192
OUT
"
"
"
"
QC
"
"
"
"
"
"
193
OUT
"
"
"
"
QD
"
"
"
"
"
"
194
"
"
"
OUT
"
QE
"
"
"
"
"
"
195
"
"
"
OUT
"
QF
"
"
"
'`
"
"
196
"
"
"
OUT
"
QG
"
"
"
'`
"
"
197
"
"
"
OUT
"
QH
See footnotes at end of device type 03.
|