| TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
MIL-
Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Meas.
Subgroup
Symbol STD-883
QC
QB
QA
VCC
QD
terminal
Min
Max
Unit
method
Test No.
CLR
SR
A
B
C
D
SL
GND
S0
S1
CLK
11
MHz
9
(Fig 8)
124
B
IN
GND
GND
GND
GND
GND
GND
5.0 V
GND
IN
OUT
5.0 V
fMAX
QA
3003
125
IN
5.0 V
5.0 V
5.0 V
5.0 V
"
"
5.0 V
"
OUT
"
7
34
ns
TC = 25C
tPHL1
CLR to QA
"
"
(Fig 8)
126
"
"
"
"
"
"
"
"
"
OUT
"
"
"
"
CLR to QB
"
"
"
"
"
"
127
"
"
"
"
"
"
"
"
"
OUT
"
CLR to QC
"
"
"
"
"
"
128
"
"
"
"
"
"
"
"
"
OUT
"
CLR to QD
"
129
B
IN
"
"
"
"
"
"
"
OUT
"
"
"
26
"
CLK to QA
tPLH2
"
"
"
130
"
5.0 V
IN
"
"
"
"
"
"
OUT
"
"
"
"
CLK to QB
"
"
"
"
"
"
131
"
5.0 V
5.0 V
IN
"
"
"
"
"
OUT
"
CLK to QC
"
"
"
"
"
"
132
"
5.0 V
5.0 V
5.0 V
IN
"
"
"
"
OUT
"
CLK to QD
"
133
5.0 V
IN
5.0 V
5.0 V
5.0 V
"
"
"
"
OUT
"
"
"
32
"
CLK to QA
tPHL2
"
"
"
134
"
5.0 V
IN
5.0 V
5.0 V
"
"
"
"
OUT
"
"
"
"
CLK to QB
"
"
"
"
"
"
135
"
5.0 V
5.0 V
IN
5.0 V
"
"
"
"
OUT
"
CLK to QC
"
"
"
"
"
"
136
"
5.0 V
5.0 V
5.0 V
IN
"
"
"
"
OUT
"
CLK to QD
9
MHz
10
(Fig 8)
137
B
IN
GND
GND
GND
GND
GND
"
5.0 V
GND
IN
OUT
"
fMAX
QA
TC = 125C
3003
138
IN
5.0 V
5.0 V
5.0 V
5.0 V
"
"
5.0 V
"
OUT
"
7
48
ns
CLR to QA
tPHL1
"
"
"
(Fig 8)
139
"
"
"
"
"
"
"
"
"
OUT
"
"
"
CLR to QB
"
"
"
"
"
"
140
"
"
"
"
"
"
"
"
"
OUT
"
CLR to QC
"
"
"
"
"
"
141
"
"
"
"
"
"
"
"
"
OUT
"
CLR to QD
"
142
B
IN
"
"
"
"
"
"
"
OUT
"
"
"
36
"
CLK to QA
tPLH2
"
"
"
143
"
5.0 V
IN
"
"
"
"
"
"
OUT
"
"
"
"
CLK to QB
"
"
"
"
"
"
144
"
5.0 V
5.0 V
IN
"
"
"
"
"
OUT
"
CLK to QC
"
"
"
"
"
"
145
"
5.0 V
5.0 V
5.0 V
IN
"
"
"
"
OUT
"
CLK to QD
"
146
5.0 V
IN
5.0 V
5.0 V
5.0 V
"
"
"
"
OUT
"
"
"
44
"
CLK to QA
tPHL2
"
"
"
147
"
5.0 V
IN
5.0 V
5.0 V
"
"
"
"
OUT
"
"
"
"
CLK to QB
"
"
"
"
"
"
148
"
5.0 V
5.0 V
IN
5.0 V
"
"
"
"
OUT
"
CLK to QC
"
"
"
"
"
"
149
"
5.0 V
5.0 V
5.0 V
IN
"
"
"
"
OUT
"
CLK to QD
11
Same tests, terminal conditions and limits as subgroup 10, except TC = -55C.
1/
A = normal clock pulse, except for subgroup 7 and 8 (see 3/).
2/
B = momentary GND, then VIN (except for subgroups 7 and 8). For subgroups 1, 2 and 3, VIN = VCC; for subgroups 9, 10 and 11, VIN = 3.0 V minimum (see figure 8).
3/
For subgroups 7 and 8, A = VCC and B = GND.
4/
Output voltages shall be either:
(a) H = 2.4 V minimum and L = 0.4 V maximum when using a high speed checker double comparator, or
(b) H ≥ 1.5 V and L < 1.5 V when using a high speed checker single comparator.
5/ The tests in subgroups 7 and 8 shall be performed in the sequence specified.
6/ Only a summary of attributes data is required.
7/ For device type 05, schematic circuits A and B, the minimum and maximum limits shall be -0.4 and -1.3 mA, respectively. For schematic C, the minimum and maximum
limits shall be -0.7 and -1.6 mA, respectively.
|